Quantification of O-(2-[18F]fluoroethyl)-L-tyrosine kinetics in glioma
Thomas Koopman1, Niels Verburg2,3, Robert C Schuit4
1Department of Radiology and Nuclear Medicine, VU University Medical Center, PO Box 7057, 1007 MB, Amsterdam, The Netherlands. t.koopman@vumc.nl.
Background:
This study identified the optimal tracer kinetic model for quantification of dynamic O-(2-[18F]fluoroethyl)-L-tyrosine ([18F]FET) positron emission tomography (PET) studies in seven patients with diffuse glioma (four glioblastoma, three lower grade glioma). The performance of more simplified approaches was evaluated by comparison with the optimal compartment model. Additionally, the relationship with cerebral blood flow-determined by [15O]H2O PET-was investigated.
Results:
The optimal tracer kinetic model was the reversible two-tissue compartment model. Agreement analysis of binding potential estimates derived from reference tissue input models with the distribution volume ratio (DVR)-1 derived from the plasma input model showed no significant average difference and limits of agreement of - 0.39 and 0.37. Given the range of DVR-1 (- 0.25 to 1.5), these limits are wide. For the simplified methods, the 60-90 min tumour-to-blood ratio to parent plasma concentration yielded the highest correlation with volume of distribution VT as calculated by the plasma input model (r = 0.97). The 60-90 min standardized uptake value (SUV) showed better correlation with VT (r = 0.77) than SUV based on earlier intervals. The 60-90 min SUV ratio to contralateral healthy brain tissue showed moderate agreement with DVR with no significant average difference and limits of agreement of - 0.24 and 0.30. A significant but low correlation was found between VT and CBF in the tumour regions (r = 0.61, p = 0.007).
Conclusion:
Uptake of [18F]FET was best modelled by a reversible two-tissue compartment model. Reference tissue input models yielded estimates of binding potential which did not correspond well with plasma input-derived DVR-1. In comparison, SUV ratio to contralateral healthy brain tissue showed slightly better performance, if measured at the 60-90 min interval. SUV showed only moderate correlation with VT. VT shows correlation with CBF in tumour.
More Related Videos
Related Concept Videos
SN2 Reaction: Kinetics
In a chemical reaction, a relationship exists between the concentration of reactants and the rate at which the reaction proceeds. The study to measure this relationship is known as the kinetics of a chemical reaction. Kinetic studies are used to deduce the rate law of a chemical reaction, which provides information about the species involved during the transition state of the rate-determining step. Thus, kinetic studies help to derive the mechanism of a...
Receptor Tyrosine Kinases
Kinetic Molecular Theory: Molecular Velocities, Temperature, and Kinetic Energy
Kinetic Energy
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...
Kinetic Friction