Related Experiment Video
Updated: Feb 7, 2026

Less-Invasive Technique for Non-stabilized Mandibular Fracture in Mouse Models
Published on: September 27, 2024
Minimally invasive stabilization of the fractured ankylosed spine: a comparative case series study
Francis Brooks1, Matthew Rackham1, Ben Williams1
1Spinal Unit, Royal Adelaide Hospital, Port Road, Adelaide, Australia.
Background:
To compare the outcome of minimally invasive fracture stabilization to traditional open methods in the thoracolumbar region in patients with an ankylosing disorder of the spine.
Methods:
A prospective, ethics-approved database (Spine Tango) at a tertiary referral center was retrospectively reviewed for results of surgery on fractures of the ankylosed thoracolumbar spine. These were then split by surgical technique into two cohorts: minimally invasive surgical fixation (MIS group) or standard open surgery (open group).
Results:
We identified 17 patients who presented with fractures in an ankylosed spine from 2010 to 2017. MIS fixation was performed on 10 and open surgery and fixation on 7. Average age in the MIS group was older than the traditional cohort. There was no difference in the average number of levels stabilized (open =6.9, MIS =7). There was a shorter duration in the operative time and a significant difference in blood loss in favor of the MIS group (P=0.00079). Radiation exposure time and dose were significantly higher in the MIS group (P=0.006). There were no cases of non-union, implant malposition or failure in either group. Two significant complications occurred with the death of one patient in the MIS group, and one death in the open group.
Conclusions:
The MIS technique for fractures of the ankylosed spine has shown an acceptable complication rate and good results comparable to open surgery for a high-risk patient population.
More Related Videos
Related Concept Videos
Nuclear Stability
To hold positively charged protons together...
RNA Stability
Resistors In Series
In a series circuit, the...
Series Resonance
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...