Related Experiment Video
Updated: Feb 7, 2026

Data Processing Methods for 3D Seismic Imaging of Subsurface Volcanoes: Applications to the Tarim Flood Basalt
Published on: August 7, 2017
Utilizing the radiometric and seismic methods for hydrocarbons prospecting in the Rancheria sub-basin in Colombia
Sonia Salazar1, Luis Castillo2, Luis Montes1
1Universidad Nacional de Colombia, Colombia.
Abstract:
An onshore radiometric survey sampled in situ the isotopes U238, Th232, K40, and Rn222 to build maps of normalized values for each element containing negative and positive radiometric anomalies, which could associate with hydrocarbon deposits in the subsoil. The vertical migration of hydrocarbon, water or other gases would have generated the different isotope anomalies. In four 2D seismic sections of the study area, three on dip direction and another in strike direction, we interpreted unconformities, flooding surface, and maximum flooding surfaces, as well as Cretaceous tops. In structural contour maps made from aforementioned seismic sections, we observe structural highs and structures such as truncations of strata. These structures in-depth coincide with uranium, thorium, potassium and radon anomalies seen on the surface. This oil and gas exploration approach that integrates radiometric and emanometric integrated with seismic prospecting can help to reduce the risk in hydrocarbons projects (however, radiometric anomalies are not uniquely associated with hydrocarbons). This work shows a correlation between radiometric (uranium, thorium, and potassium) and emanometric (radon) data in the surface with structures in the subsurface suck like truncation, that could present hydrocarbon, however, on this sub-basin, there has not been found commercial hydrocarbon.
More Related Videos
Related Concept Videos
Radioactive Decay and Radiometric Dating
Aromatic Hydrocarbon Anions: Structural Overview
Due to the absence of continuous...
Aromatic Hydrocarbon Cations: Structural Overview
Removing one hydrogen from the intervening CH2 group...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
The Scientific Method
The Scientific Method
Generally, predictions are tested using carefully-designed experiments. Based on the outcome of these...

