Related Experiment Video
Updated: Feb 7, 2026

Taste Exam: A Brief and Validated Test
Published on: August 17, 2018
Instrument completion and validation of the patient-reported apnea questionnaire (PRAQ)
Inger L Abma1, Maroeska Rovers2, Marijke IJff3
1Radboud Institute of Health Sciences, IQ healthcare, Radboud University Medical Center, PO box 9101, huispost 114, 6500, HB, Nijmegen, the Netherlands. Inger.abma@radboudumc.nl.
Background:
We previously developed the preliminary version of the Patient-Reported Apnea Questionnaire (PRAQ), a questionnaire measuring health-related quality of life in patients with (suspected) obstructive sleep apnea (OSA). This questionnaire was developed for clinical practice, where it can potentially serve two goals: use on an individual patient level to improve patient care, and use on an aggregate level to measure outcomes for quality improvement at a sleep center. In this study we aim to finalize the PRAQ, make a subselection of items and domains specifically for outcome measurement, and assess the validity, reliability and responsiveness of the PRAQ.
Methods:
Patients with suspected OSA were included and asked to complete the PRAQ and additional questionnaires one or more times. The collected data was used to perform the final item selection for clinical practice and for outcome measurement, create the domains for outcome measurement, and assess the measurement properties internal consistency, test-retest reliability, convergent validity and responsiveness.
Results:
180 patients were included in the study. The final version of the PRAQ for use in clinical practice contains 40 items and 10 domains. A subselection of 33 items in 5 domains was selected for optimal outcome measurement with the PRAQ. The results for the outcome measurement domains were: Cronbach's alpha 0.88-0.95, ICC 0.81-0.88, and > 75% of hypotheses correct for convergent validity and responsiveness.
Conclusions:
The PRAQ shows good measurement properties in patients with (suspected) OSA.
More Related Videos
07:54Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Reliability and Validity
Uncertainty in Measurement: Reading Instruments
Data Reporting and Recording
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...