Related Experiment Video
Updated: Feb 6, 2026

Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Fluorescein Aqueous Angiography in Live Normal Human Eyes
Alex S Huang1, Rafaella C Penteado2, Sajib K Saha1
1Department of Ophthalmology, Doheny Eye Institute, David Geffen School of Medicine at UCLA, Los Angeles.
Purpose:
To evaluate aqueous humor outflow (AHO) in intact eyes of live human subjects during cataract surgery using fluorescein aqueous angiography.
Methods:
Aqueous angiography was performed in 8 live human subjects (56 to 86 y old; 2 men and 6 women). After anesthesia, fluorescein (2%) was introduced into the eye [either alone or after indocyanine green (ICG; 0.4%)] from a sterile, gravity-driven constant-pressure reservoir. Aqueous angiographic images were obtained with a Spectralis HRA+OCT and FLEX module (Heidelberg Engineering). Using the same device, anterior-segment optical coherence tomography (OCT) and infrared images were also concurrently taken with aqueous angiography.
Results:
Fluorescein aqueous angiography in the live human eye showed segmental AHO patterns. Initial angiographic signal was seen on average by 14.0±3.0 seconds (mean±SE). Using multimodal imaging, angiographically positive signal colocalized with episcleral veins (infrared imaging) and intrascleral lumens (anterior-segment OCT). Sequential aqueous angiography with ICG followed by fluorescein showed similar segmental angiographic patterns.
Discussion:
Fluorescein aqueous angiography in live humans was similar to that reported in nonhuman primates and to ICG aqueous angiography in live humans. As segmental patterns with sequential angiography using ICG followed by fluorescein were similar, these tracers can now be used sequentially, before and after trabecular outflow interventions, to assess their effects on AHO in live human subjects.
Related Concept Videos
Chemical Reactions in Aqueous Solutions
Aqueous Solutions and Heats of Hydration
When ionic compounds dissolve in water, the ions in the solid separate and disperse uniformly throughout the solution because water molecules surround and solvate the ions, reducing the strong electrostatic forces between them. This process...
Normal Distribution
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...
Applications of Normal Distribution
The heights of 15 to 18-year-old males from Chile from 1984 to 1985 followed a normal distribution. The mean height is 172.36...
Introduction to Normal Distributions

