Accurate detection of atrial fibrillation and atrial flutter using the electrocardiomatrix technique
Veronica Lee1, Gang Xu1, Vivian Liu1
1Department of Molecular and Integrative Physiology, University of Michigan Medical School, Ann Arbor, MI, USA.
Background:
Atrial fibrillation (AFIB) and atrial flutter (AFL) are two common cardiac arrhythmias that predispose patients to serious medical conditions. There is a need to accurately detect these arrhythmias to prevent diseases and reduce mortality. Apart from accurately detecting these arrhythmias, it is also important to distinguish between AFIB and AFL due to differing clinical treatments.
Methods:
In this study, we applied a new technology, the electrocardiomatrix (ECM) invented in our lab, in detecting AFIB and AFL in human patients. ECM converts 2D ECG signals into a 3D color matrix, which renders arrhythmia detection intuitive, fast, and accurate. Using ECM, we analyzed the ECG signals from the online MIT-BIH Atrial Fibrillation Database (PhysioNet), and compared our ECM-based results to manual annotations based on ECG by physicians.
Results:
Results demonstrate that ECM and PhysioNet annotations of AFIB and AFL agree more than 99% of the time. The sensitivities of the ECM for AFIB and AFL detection were 99.2% and 98.0%, respectively, and the specificities of the ECM for AFIB and AFL were both at 99.8% and 99.8%.
Conclusions:
This study demonstrates that ECM is a reliable method for accurate identification of AFIB and AFL.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...