Related Experiment Video
Updated: Feb 6, 2026

Author Spotlight: Enhancing Transplantation Research Through MicroCT Angiography in Murine Models
Published on: September 22, 2023
Comparisons by microcomputed tomography of the efficiency of different irrigation techniques for removing dentinal
Francine Cesario1, Marco Antonio Hungaro Duarte1, Jussaro Alves Duque1
1Department of Restorative Dentistry, Dental Materials and Endodontics, Bauru Dental School, University of Sao Paulo, Bauru, Sao Paulo, Brazil.
Aim:
The aim of this study was compare the capacity of different irrigation protocols for debris removal from artificial grooves and assess the effectiveness of Easy Clean used in different kinematics by means of micro-CT.
Methodology:
Fifty acrylic prototyped maxillary incisors were instrumented and included in a muffle. The specimens were longitudinally sectioned, and a longitudinal groove was made on the inner surface of the root canal in one of hemisections, and the dentin debris was inserted into the grooves. The specimens were divided into five groups (n = 10): G1: Conventional with open-ended needle; G2: Conventional with double side-vented needle; G3: Easy Clean in reciprocating movement; G4: Easy clean in continuous rotation (ECCR); and G5: Passive ultrasonic irrigation (PUI). All specimens were scanned using microcomputed tomography before and after the irrigation technique and calculated the volume (mm3) of dentin debris. The paired t-test and post hoc Tukey test were the statistical tests used, with significance set at 5%.
Results:
There were no significant difference (P > 0.05) between PUI and ECCR. ECCR was significantly (P < 0.05) more effective than the groups of conventional irrigation techniques.
Conclusions:
PUI and ECCR favored the removal of a larger volume of dentin debris from the groove.
More Related Videos
Related Concept Videos
Design Example: Design of an Irrigation Channel
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Natural and Artificial Concepts
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...