Related Experiment Video
Updated: Feb 6, 2026

Orthopedic Robot-Assisted Femoral Neck System in the Treatment of Femoral Neck Fracture
Published on: March 3, 2023
Linear and nonlinear analyses of femoral fractures: Computational/experimental study
Majid Mirzaei1, Fatemeh Alavi1, Farzaneh Allaveisi1
1Department of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran.
Abstract:
This paper describes two new methods for computational fracture analysis of human femur using Quantitative Computed Tomography (QCT) voxel-based finite element (FE) simulation. The paper also reports comprehensive mechanical testing for validation of the methods and evaluation of the required material properties. The analyses and tests were carried out on 15 human femurs under 11 different stance-type loading orientations. Several classical forms of subcapital, transcervical, basicervical, and intertrochanteric fractures plus a specific type of subtrochanteric fracture were created and analyzed. A new procedure was developed for prediction of the strengths and the fracture initiation patterns using a FE-based linear scheme. The predicted and observed fracture patterns were in correspondence, and the FE predictions of the fracture loads were in very good agreement with the experimental results. Moreover, the crack initiation and growth behaviors of two subtrochanteric fractures were successfully simulated through a novel implementation of the cohesive zone model (CZM) within a nonlinear FE analysis scheme. The CZM parameters were obtained through a series of experimental tests on different types of specimens and determination of a variety of material properties for different anatomic regions and orientations. The presented results indicated that the locations and patterns of crack initiation, the sequences of crack growth on different paths, and the compatibility of growth increments agreed very well with the observed specifications. Also, very good agreements were achieved between the measured and simulated fracture loads.
Related Concept Videos
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Imaging Studies III: Computed Tomography
Application of Nonlinear Inequalities
Introduction to Nonlinear Inequalities
Nonlinear Pharmacokinetics: Overview
Nonlinearity can arise due to the saturation of plasma protein-binding or...
Linear Circuits

