Related Experiment Video
Updated: Feb 6, 2026

13:35
Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
4.3K
Robotic Nipple-Sparing Mastectomy and Immediate Breast Reconstruction with Gel Implant
1Endoscopic and Oncoplastic Breast Surgery Center, Changhua Christian Hospital, Changhua, Taiwan. 143809@cch.org.tw.
Annals of Surgical Oncology
|August 27, 2018
Abstract
No abstract available in PubMed .
Related Concept Videos
Spare Receptors
4.6K
Some receptors remain unoccupied even when an agonist produces a maximal response. Such empty ones are called spare receptors. In presence of spare receptors the maximum effect of an agonist drug is achieved with fewer than 100% of the receptors being occupied. To determine the presence of spare receptors, scientists often compare the concentration of the drug needed to produce 50% of the maximum effect (EC50) with the concentration of the drug needed to occupy 50% of the receptors (Kd). If the...
4.6K
Antihypertensive Drugs: Potassium-Sparing Diuretics
2.3K
Liddle syndrome is a genetically inherited form of hypertension characterized by the overactivity of epithelial sodium channels in the nephron, the functional unit of the kidney. This heightened activity leads to increased sodium reabsorption and excessive excretion of potassium. To counteract this, potassium-sparing diuretics such as amiloride are used. They function by blocking these sodium channels, thereby reducing the influx of sodium into the epithelial cells and minimizing the loss of...
2.3K
Reconstruction of Signal using Interpolation
734
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
734
Two-dimensional Gel Electrophoresis
7.5K
Two-dimensional gel electrophoresis is a high-resolution protein separation method first introduced by O' Farrell and Klose in 1975. This method involves protein separation by two dimensions, mass and charge, making it more accurate than one-dimensional gel electrophoresis.
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
7.5K
DNA Agarose Gel Electrophoresis
113.8K
Agarose gel electrophoresis is a laboratory technique commonly used to separate DNA fragments by size. However, it can also be used to isolate and purify DNA fragments using a gel extraction protocol.
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
113.8K
Silica Gel Column Chromatography: Overview
3.6K
Silica gel column chromatography is a technique for separating compounds using a column packed with silica gel as the stationary phase. This method relies on differences in the polarity of compounds. Based on their polarities, compounds move between the stationary phase (silica gel) and the mobile phase (the solvent), forming discrete bands in the column.
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
3.6K

