Related Experiment Video
Updated: Feb 6, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Investigating hydrophilic and electrostatic properties of surfactants using retention on two mixed-mode liquid
J Hammer1, J J-H Haftka2, P Scherpenisse2
1Institute for Risk Assessment Sciences, Utrecht University, P.O. Box 80177, 3508 TD Utrecht, The Netherlands; Institute for Biodiversity and Ecosystem Dynamics, University of Amsterdam, P.O. Box 94248, 1090 GE Amsterdam, The Netherlands.
Abstract:
In environmental risk assessment, it is essential to understand the relationship between molecular structure and fate and toxicity of organic contaminants. For surfactants, physico-chemical parameters which can reflect the interactions that determine surfactant behavior are not well defined and are therefore needed for the development of robust quantitative structure-activity relationships (QSAR). For the present study, we have measured HPLC retention times of several hydrocarbon and perfluorocarbon surfactant groups on a mixed-mode weak anion-exchange (WAX) and mixed-mode hydrophilic interaction liquid chromatography (HILIC) stationary phase. The nonionic alcohol ethoxylates are well retained on the HILIC column. Retention of anionic surfactants on the HILIC column is likely influenced by the degree of hydration of the surfactants and electrostatic repulsion from silanol groups. Less hydrated anionic surfactants (perfluoroalkyl carboxylates, perfluoroalkyl sulfonates and alkyl sulfates) show minimal hydrophilic interaction while other better hydrated anionic surfactants (alkyl carboxylates and alkyl sulfonates) are well retained. The retention mechanism of surfactants on both columns seems to be related to their degree of hydration, albeit expressed in different retention behavior: generally, retention on the WAX phase increases when retention on the HILIC phase decreases, and vice versa. The retention times from both columns were used to calculate retention factors (k') and these were subsequently used in calculating parameters that reflect the electrostatic property (kAX) and hydrophilic property (kHILIC) that determine the interaction between the hydrophilic part of the surfactant and the stationary phase. In further development of predictive models, we suggest the use of kAX for anionic surfactants and kHILIC for nonionic surfactants.
More Related Videos
10:44One-step Negative Chromatographic Purification of Helicobacter pylori Neutrophil-activating Protein Overexpressed in Escherichia coli in Batch Mode
Published on: June 18, 2016
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Electrostatic Boundary Conditions
The surface integral of an electric field is given by Gauss's law in integral form and is related to...