Related Experiment Video
Updated: Feb 5, 2026

A Bright NIR-II Fluorescence Probe for Vascular and Tumor Imaging
Published on: March 17, 2023
High Photostability in Nonconventional Coumarins with Far-Red/NIR Emission through Azetidinyl Substitution
Albert Gandioso1, Marta Palau1, Roger Bresolí-Obach2
1Secció de Química Orgànica, Departament de Química Inorgànica i Orgànica, IBUB , Universitat de Barcelona , Martí i Franquès 1-11 , E-08028 Barcelona , Spain.
Abstract:
Replacement of electron-donating N,N-dialkyl groups with three- or four-membered cyclic amines (e.g., aziridine and azetidine, respectively) has been described as a promising approach to improve some of the drawbacks of conventional fluorophores, including low fluorescent quantum yields (ΦF) in polar solvents. In this work, we have explored the influence of azetidinyl substitution on nonconventional coumarin-based COUPY dyes. Two azetidine-containing scaffolds were first synthesized in four linear synthetic steps and easily transformed into far-red/NIR-emitting fluorophores through N-alkylation of the pyridine moiety. Azetidine introduction in COUPY dyes resulted in enlarged Stokes' shifts with respect to the N,N-dialkylamino-containing parent dyes, but the ΦF were not significantly modified in aqueous media, which is in contrast with previously reported observations in other fluorophores. However, azetidinyl substitution led to an unprecedented improvement in the photostability of COUPY dyes, and high cell permeability was retained since the fluorophores accumulated selectively in mitochondria and nucleoli of HeLa cells. Overall, our results provide valuable insights for the design and optimization of novel fluorophores operating in the far-red/NIR region, since we have demonstrated that three important parameters (Stokes' shifts, ΦF, and photostability) cannot be always simultaneously addressed by simply replacing a N,N-dialkylamino group with azetidine, at least in nonconventional coumarin-based fluorophores.
More Related Videos
08:18Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions
Published on: June 12, 2016
10:30Simultaneously Capturing Real-time Images in Two Emission Channels Using a Dual Camera Emission Splitting System: Applications to Cell Adhesion
Published on: September 4, 2013
Related Concept Videos
Emission Spectra
Trigonometric Substitution
Rationalizing Substitutions
Red Algae
Diazonium Group Substitution: –OH and –H
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...