Related Experiment Video
Updated: Feb 5, 2026

A Coregistered Ultrasound and Photoacoustic Imaging Protocol for the Transvaginal Imaging of Ovarian Lesions
Published on: March 3, 2023
Comparison of reliability between uterocervical angle and cervical length measurements by various experienced
Ninlapa Pruksanusak1, Rapphon Sawaddisan1, Ounjai Kor-Anantakul1
1Department of Obstetrics and Gynecology, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand.
Abstract:
Purpose: To compare the reliability between uterocervical angle (UCA) and cervical length (CL) measurements by various experienced operators.Methods: Transvaginal ultrasonographies (TVS) were performed in 102 pregnant women between 16°/7-24°/7 gestational weeks by different levels of experienced operators. For both CL and UCA measurements, intraobserver variability was assessed for each operator by examining the range between maximum and minimum measurements in each participant, compared to the mean of all three measurements. Interobserver variabilities were explored using Bland-Altman analysis. Intraclass correlation coefficients were used for both intraobserver and interobserver reliability.Results: For intraobserver variability of the UCA, the ranges between maximum and minimum UCA measurements in operator 1 and 3 were 1.5º-34º and 2º-36º (n = 51), and in operators 2 and 3 were 0º-61º and 1º-25º (n = 51). Intraclass correlation coefficients (ICC) for intraobserver reliability were 0.90 for operator 1, 0.67 for operator 2 and 0.93 for operator 3. For interobserver variability of the UCA, the limits of agreement for mean UCA were -37.53º-38.41º and -36.27º-26.17º, and for maximum UCA were -39.47º-41.38º and -44.24º-22.9º in comparisons between operators 1 and 3, and operator 2 and 3, respectively. Intraclass correlation coefficients for mean UCA were 0.73 and 0.74, and for maximum UCA were 0.71 and 0.67 in comparisons between operators 1 and 3, and operator 2 and 3, respectively.Conclusions: The UCA measurements had a higher intra- and interobserver reliabilities than the CL measurements.
Related Concept Videos
Reliability and Validity
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Distribution Reliability and Automation
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle of Twist: Problem Solving

