Related Experiment Video
Updated: Feb 5, 2026

Absolute Quantum Yield Measurement of Powder Samples
Published on: May 12, 2012
[Measurement of Soot Yield from the Pyrolysis of Toluene at High Temperatures by Laser Extinction Method]
Abstract:
The measurement system for the detection of soot production as high-temperature pyrolysis of hydrocarbon fuels behind the reflected shock wave was established. By using the laser extinction method, the soot yields of toluene/argon mixtures were measured at high temperatures. The mole fractions of toluene were 0.25% and 0.5% while the pressures were approximate 2 and 4 atm. The temperatures ranged from 1 630 to 2 273 K. The dependence of soot yield on the temperature, pressure and fuel concentration was obtained. With the changes of temperature, the soot yield is a Gauss distribution. The soot yield increases as the pressure or fuel concentration increases. The maximum of soot yield was as high as 55%. The peak temperature of soot yield was not changed dramatically with the pressure. However, it changed from 1 852 to 1 921 K as the concentration of toluene increase from 0.25% to 0.5%. Moreover, we compared the soot yield between toluene and methylcyclohexane at pressure of 4 atm with fuel concertation of 0.5%. During the pyrolysis of methylcyclohexane, the peak temperature of soot yield was 2 045 K, which is about 135 K higher than that of toluene. However, the maximum soot yield of methylcyclohexane is only 1/8 of toluene. This work provides experimental reference for the research of soot particle emission in the engines and the mechanism of soot formation.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
ATP Yield
The ETC is embedded in the inner mitochondrial membrane and is comprised of four main protein complexes and an ATP synthase. NADH and FADH2 pass electrons to these complexes, which pump protons into the intermembrane space. This distribution of...
Reaction Yield
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Generalization, Discrimination, and Extinction
Generalization occurs when a behavior reinforced in one context is performed in similar situations. For instance, a student who studies diligently for calculus and receives excellent grades might apply the same study habits to psychology and history, expecting similar results. Generalization shows how learning in one setting can influence behavior in...
Physical Methods for Controlling Microbial Growth: Temperature

