Related Experiment Video
Updated: Feb 5, 2026

Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Increased Plasma-Free Hemoglobin Levels Identify Hemolysis in Patients With Cardiogenic Shock and a Trans valvular
Michele L Esposito1,2,3, Kevin J Morine1,2,3, Shiva K Annamalai1,2,3
1The Molecular Cardiology Research Institute, Boston, MA, USA.
Abstract:
Hemolysis is a potential limitation of percutaneously delivered left-sided mechanical circulatory support pumps, including trans valvular micro-axial flow pumps (TVP). Hemolytic biomarkers among durable left ventricular assist devices include lactate dehydrogenase (LDH) >2.5 times the upper limit of normal (ULN) and plasma-free hemoglobin (pf-Hb) >20 mg/dL. We examined the predictive value of these markers among patients with cardiogenic shock (CS) receiving a TVP. We retrospectively studied records of 116 consecutive patients receiving an Impella TVP at our institution between 2012 and 2017 for CS. Twenty-three met inclusion/exclusion criteria, and had sufficient pf-Hb data for analysis. Area under receiver-operator characteristic (ROC) curve for diagnosing hemolysis were calculated. Mean age was 62 ± 14 years and ejection fraction was 15 ± 5%. Mean duration of support was 5.4 ± 3.5 days. Pre-device LDH levels were >2.5x ULN in 71% (n = 5/7) of 5.0 and 29% of CP patients, while pre-device pf-Hb levels were >20 mg/dL in 14% (n = 1/7) of 5.0 and 25% (n = 4/16) of CP patients. Given elevated baseline LDH and pf-Hb levels, we defined hemolysis as a pf-Hb level >40 mg/dL within 72 h post-implant plus clinical evidence of device-related hemolysis. We identified that 30% (n = 7/23) had device-related hemolysis. Using ROC curve-derived cut-points, an increase in delta pf-Hb by >27mg/dL, not delta LDH, within 24 h after TVP implant (delta pf-Hb: C-statistic = 0.79, sensitivity: 57%, specificity: 93%, p <0.05) was highly predictive of hemolysis. In conclusion, we identified a change in pf-Hb, not LDH, levels is highly sensitive and specific for hemolysis in patients treated with a TVP for CS.
More Related Videos
Related Concept Videos
Hemoglobin
When all four heme groups are bound to oxygen, the resulting molecule is called oxyhemoglobin. As a result, arterial blood...
Axial and Appendicular Muscles
Axial Muscles
Axial muscles, situated along the body's midline, are intricately connected to the axial skeleton, which includes the skull, spine, ribs, and sternum. These muscles facilitate facial expressions and...
Factors Affecting Renal Clearance: Drug's Physicochemical Properties and Plasma Levels
One important factor is the drug's molecular size. The kidneys readily excrete smaller molecules below 300 Daltons (Da). On the other hand, molecules weighing between 300 and 500 Da are excreted through both urine and bile. Larger molecules above 500 Da tend to be excreted...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...