Limitations of platform assays to measure serum 25OHD level impact on guidelines and practice decision making
Maya Rahme1, Laila Al-Shaar1, Ravinder Singh2
1Department of Internal Medicine, Division of Endocrinology, Calcium Metabolism and Osteoporosis Program, WHO Collaborating Center for Metabolic Bone Disorders, American University of Beirut Medical Center, Beirut, Lebanon.
Context:
Liquid Chromatography Mass Spectroscopy (LC-MS/MS) is the preferred method to measure 25 hydroxyvitamin D (25OHD) levels, but laboratories are increasingly adopting automated platform assays.
Objective:
We assessed the performance of commonly used automated immunoassays, with that of LC-MS/MS, and the National Institute of Standards and Technology (NIST) reference values, to measure 25OHD levels.
Methods/Setting:
We compared serum 25OHD levels obtained from 219 elderly subjects, enrolled in a vitamin D trial, using the Diasorin Liaison platform assay, and the tandem LC-MS/MS method. We also assessed the performance of the Diasorin and Roche automated assays, expressed as mean % bias from the NIST standards, based on the vitamin D External Quality Assessment Scheme (DEQAS) reports, from 2013 to 2017.
Results:
Serum 25OHD levels were significantly lower in the Diasorin compared to LC-MS/MS assay at baseline, 18.5 ± 7.8 vs 20.5 ± 7.6 ng/ml (p < 0.001), and all other time points. Diasorin (25OHD) = 0.76 × LC-MS/MS (25OHD) + 4.3, R2 = 0.596. The absolute bias was independent of 25OHD values, and the pattern unfit for any cross-calibration. The proportion of subjects considered for vitamin D treatment based on pre-set cut-offs differed significantly between the 2 assays. There also was wide variability in the performance of both automated assays, compared to NIST reference values.
Conclusion:
The performance of most widely used automated assays is sub-optimal. Our findings underscore the pressing need to re-consider current practices with regard to 25OHD measurements, interpretation of results from research studies, meta-analyses, the development of vitamin D guidelines, and their relevance to optimizing health.
More Related Videos
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Nominal Level of Measurement
The data that cannot be measured but can be grouped into categories fall under the nominal level of measurement. Data that is measured using a nominal...
Limiting Reactant