Related Experiment Video
Updated: Feb 5, 2026

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
Published on: May 25, 2020
Compliance With Primary Open-angle Glaucoma and Primary Open-angle Glaucoma Suspect Preferred Practice Patterns in a
Jordan Stanley1, Carrie E Huisingh1, Thomas A Swain1
1Department of Ophthalmology and Visual Sciences, School of Medicine.
Purpose:
To determine the level of adherence to the American Academy of Ophthalmology preferred practice pattern (PPP) guidelines for quality primary open-angle glaucoma (POAG) and POAG suspect (POAGS) care among retail-based optometrists.
Methods:
Patients with a diagnosis of POAG or POAGS who participated in a telemedicine pilot project were included. Patients' charts were evaluated for 15 elements of PPP guidelines for glaucoma care. Results were further stratified by number of follow-up visits and diagnosis.
Results:
Of 360 identified patients, 10 elements were documented in over 98%. Documentation of the remaining 5 components was as follows: dilated fundus examination 91.1%, central corneal thickness (CCT) 88.6%, visual field 78.9%, gonioscopy 47.5%, and target intraocular pressure (IOP) 15.6%. in total, 32.8% of patients were seen once, whereas the remaining 67.2% had multiple visits. In patients with multiple visits, providers were more likely to document systemic history (100.0% vs. 97.5%; P=0.0346), review of systems (100.0% vs. 97.5%; P=0.0346), gonioscopy (60.0% vs. 22.0%; P<0.001), CCT (94.2% vs. 77.1%; P<0.001), visual field (97.5% vs. 40.7%; P<0.001), and target IOP (22.4% vs. 1.7%; P<0.001) compared with single visit patients. In stratifying results by diagnosis, POAG patients more often received visual field testing (92.7% vs. 68.9%; P<0.001) and had an established target IOP (35.1% vs. 1.4%; P<0.001) compared with POAGS patients.
Conclusions:
Compliance with PPP guidelines for glaucoma care was very high for most elements but lower for performing dilated fundus examination, CCT, visual field, gonioscopy, and target IOP. This study highlights deficiencies in care likely to hamper the detection of glaucoma progression.
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Glaucoma: Overview
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Angle of Twist: Problem Solving
Design Example: Traverse Angle Computations

