Clinical and dosimetric consequences of imperfect applicator insertion in cervical cancer brachytherapy
Bikramjit Chakrabarti1, Suparna Kanti Pal1, Harris Mahammad Sepai1
1Department of Radiotherapy, Institute of Post-Graduate Medical Education and Research and Seth Sukhlal Kernani Memorial Hospital, Kolkata, India.
Purpose:
This study analyzes clinical consequences and dosimetric variations after imperfect brachytherapy insertions. It examines treatment decisions after such insertions in patients having difficult anatomy, which leads to good subsequent insertions with acceptable dose volume parameters.
Material And Methods:
We reviewed images of all insertions performed during last one year and sorted faulty ones out. Clinical outcome was assessed, analyzing original treatment records. Repeat three-dimensional planning using identical dose-optimization-technique compared their dosimetry. Statistical analysis using SPSS®-Statistics-software included Fisher's-exact-test to analyze predisposing factors for faulty insertions and predictive factors for subsequent satisfactory insertion. Friedman test was used to compare dose-volume-effects of normalization.
Results:
Eighteen of 292 brachytherapy plans revealed imperfect insertions, including thirteen perforations (4.5%). Lack of pre-planning, obstructing mass, narrow vagina, acute anteversion of uterus, and multi-parity were significant (p ≤ 0.05) predisposing factors for atypical insertions. Satisfactory optimization was possible after correcting acute anteflexion or positioning tandem in retroverted direction in uncorrectable retroverted uterus. Dose normalization at point A shifted optimized dose from contoured volume to point of normalization, often undesirably. This difference, however, was statistically not significant (p = 0.121). In patients having obstructing mass, subsequent insertions were perfect, and dose volume parameters were acceptable only when full prescribed dose was delivered to at least 60% volume of the mass after a faulty insertion (p < 0.001).
Conclusions:
Pre-planning by imaging is suggested in all cases of brachytherapy. Insertion of adequate length of tandem aligned to uterine axis is warranted for adequate tumor coverage. Whenever detected, acute anteflexion and mobile retroversion should be corrected. Tandem inserted in retroverted direction in uncorrectable retroverted uterus generates acceptable dose volume parameters. In cases with obstructive cervical mass, good subsequent insertion is possible with acceptable dose volume parameters, if planned dose can be delivered to its 60% volume.
Related Concept Videos
Clinical Applications of Epidermal Stem Cells
Timing and Consequences on Behavior
Humans, however, can respond to delayed reinforcers. We often make decisions between immediate small rewards and delayed larger rewards. This ability to delay gratification is a significant...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Local Anesthetics: Clinical Application as Surface, Infiltration, and Conduction Block Anesthesia