Related Experiment Video
Updated: Feb 5, 2026

Optimized Sealing Process and Real-Time Monitoring of Glass-to-Metal Seal Structures
Published on: September 2, 2019
Electrospray Generated from the Tip-Sealed Fine Glass Capillary Inserted with an Acupuncture Needle Electrode
Dilshadbek T Usmanov1,2, Satoshi Ninomiya3, Kenzo Hiraoka4
1Clean Energy Research Center, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi, 400-8511, Japan.
Abstract:
In electrospray, excess charges are supplied to a sample solution by the occurrence of electrochemical reactions. Recently, different versions of electrospray, e.g., dielectric barrier electrospray ionization, inductive desorption electrospray ionization, and electrostatic-ionization driven by dielectric polarization, have been reported in which the sample solution was not in direct contact with the metal electrode but separated by dielectric materials. The objective of the current work is to elucidate the mechanism of dielectric barrier electrospray. A sealed borosilicate glass capillary inserted with a fine acupuncture needle was used as a probe. A sample solution (~ 400 nL) was captured on the glass capillary tip and a positive high voltage (HV) pulse (+ 4.5 kV) was applied to the internal metal electrode. Mass spectra were measured as a function of the HV pulse width from μs to 10 s. Ions started to be detected with the pulse width of ~ 5 ms. The ion intensities increased slowly with time and reached a plateau in a few seconds. The charge distribution of cytochrome c [M + nH]n+ shifted to higher n values from a few ms to seconds. In addition to cone-jet mode normal electrospray that lasted until all the liquid sample was depleted from the glass tip, the polarization-induced electrospray ionization was observed at the early stage of the HV application. Graphical Abstract ᅟ.
More Related Videos
08:15Fabrication of Fine Electrodes on the Tip of Hypodermic Needle Using Photoresist Spray Coating and Flexible Photomask for Biomedical Applications
Published on: November 28, 2017
08:27Three-Dimensional Finger Motion Tracking during Needling: A Solution for the Kinematic Analysis of Acupuncture Manipulation
Published on: October 28, 2021
Related Concept Videos
The Looking Glass Self
Fineness of Cement
Direct...
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Standard Electrode Potentials
Capillary Beds
Capillaries connect arterioles, small branches of arteries, to venules,...