Related Experiment Video
Updated: Feb 5, 2026

Author Spotlight: A Stable Phantom Material for Optical and Acoustic Imaging
Published on: June 16, 2023
Development of a novel algorithm for metal artifact reduction in digital tomosynthesis using projection-based
Tsutomu Gomi1, Rina Sakai1, Masami Goto1
1School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa, Japan.
Abstract:
In this study, a novel dual-energy (DE) material decomposition reconstruction algorithm (DEMDRA) was developed using projection data with the aim of reducing metal artifacts during digital tomosynthesis (DT) for implants. Using the three-material decomposition method and decomposition projection data specific for each material, a novel DEMDRA was implemented to reduce metal artifacts via weighted hybrid reconstructed images [maximum likelihood expectation maximization (MLEM) and shift-and-add (SAA)]. Pulsed X-ray exposures with rapid switching between low and high tube potential kVp were used for DE-DT imaging, and the images were compared using conventional filtered back projection (FBP), MLEM, the simultaneous algebraic reconstruction technique total variation (SART-TV), virtual monochromatic processing, and metal artifact reduction (MAR)-processing algorithms. The reductions in metal artifacts were compared using an artifact index (AI), Gumbel distribution of the largest variations, and the artifact spread functions (ASFs) for prosthesis phantom. The novel DEMDRA yielded an adequately effective overall performance in terms of the AI, and the resulting images yielded good results independently of the type of metal used in the prosthetic phantom, as well as good noise artifact removal, particularly at greater distances from metal objects. Furthermore, the DEMDRA represented the minimum in the model of largest variations. Regarding the ASF analysis, the novel DEMDRA yielded superior metal artifact reduction when compared with conventional reconstruction algorithms with and without MAR processing. Finally, the DEMDRA was particularly useful for reducing high-frequency artifacts.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
11:29Real-time Video Projection in an MRI for Characterization of Neural Correlates Associated with Mirror Therapy for Phantom Limb Pain
Published on: April 20, 2019
Related Concept Videos
Synthesis and Decomposition Reactions
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Alkali Metals
Table 1: Properties of the alkali metals
Bonding in Metals
Oxidation-Reduction Reactions
Energy Basics