Related Experiment Video
Updated: Feb 4, 2026

Basics of Multivariate Analysis in Neuroimaging Data
Published on: July 24, 2010
Dealing with overlapped and unaligned chromatographic peaks by second-order multivariate calibration for complex
Xiao-Li Yin1, Hui-Wen Gu2, Ali R Jalalvand3
1College of Life Sciences, Yangtze University, Jingzhou 434025, China.
Abstract:
The quantification of preservatives in cosmetics has attracted great attentions for their controversial and widespread use. HPLC is a prevailing method for preservatives determination among various analytical methods. However, it takes long time to fully separate these compounds because of the complexity of cosmetic matrices. In this study, a fast and green HPLC-DAD strategy assisted with second-order multivariate calibration methods based on alternating trilinear decomposition (ATLD) and multivariate curve resolution-alternating least squares (MCR-ALS) was developed for the simultaneous determination of eight selected preservatives in complex facial mask samples. This appealing strategy proved to be a useful tool for eliminating unknown interferences in complex matrices without complete separation, which benefited from the "second-order advantages" and thus made the determination of the eight analytes in facial mask samples shorten to 8.2 min under a fast elution program. In particular, for the first time, we focused on the applicability of ATLD method for modeling of HPLC-DAD data with severe signal overlapping and slight time shifts. The spiked recovery values were in the range of 71.4-124.6%, and the RMSEP and REP values ranged from 0.07 to 2.4 μg mL-1 and 1.3-14.5%, respectively, indicating that the ATLD method could provide satisfactory prediction. The resolved spectral profiles and concentration values were compared with those obtained by the MCR-ALS method, an excellent tool for modeling of data deviating from trilinearity. Both qualitative and quantitative results from the two methods were consistent with each other, which evidenced the competence of ATLD method in handling HPLC-DAD data with severe signal overlapping and slight time shifts.
More Related Videos
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...