Effect of hemostatic device on radial artery occlusion: A randomized comparison of compression devices in the radial
Kintur A Sanghvi1, Mathew Montgomery2, Vincent Varghese1
1Department of Interventional Cardiology, Deborah Heart & Lung Center, United States of America.
Background:
Asymptomatic radial artery occlusion (RAO) is a major limitation of transradial catheterization (TRC). Two radial compression hemostatic devices are compared for their respective effects on RAO.
Methods:
In a prospective, randomized, single center, blinded trial, 320 patients were randomly treated with a TR band (Terumo Corporation) or Safeguard Radial (Merit Medical). Institution wide protocols consisting of anticoagulation, patent hemostasis, duration of compression, and use of 6 French slender sheaths (Terumo Corporation) were observed. Patient discomfort related to the device was recorded using the universal pain scale. Radial artery patency was evaluated by reverse Barbeau's test prior to discharge (1-hour post-diagnostic catheterization or 6-24 hour post-intervention) and at 30-days.
Results:
Of the 320 patients, 155 were randomized to the TR group (TRG) and 159 to the Safeguard group (SGG). 6 patients were excluded due to the inability to insert 6 Fr slender sheaths or patient withdrawing consent. Demographic and procedural characteristics were similar with the exception of the type of coronary procedure performed. Both bands were equally effective in achieving patent hemostasis. Despite having a higher rate of post-procedure hematoma (1.29% TRG vs. 3.1% SGG, p = 0.04) and acute RAO (3.8% TRG vs. 6.28% SGG, p = 0.05) with the Safeguard band, at 30 days RAO was similar in both groups (1.9% TRG vs. 2.5% SGG; p = 0.21). Patients in the SGG reported significantly less band discomfort and were found to require less air to achieve patent hemostasis.
Conclusion:
Evidence-based contemporary TRC protocols of using smaller diameter access, anticoagulation, and use of just enough pressure for the shortest duration of time to achieve hemostasis is associated with very low RAO rate at 30 days irrespective of the radial compression device used.
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.