Related Experiment Video
Updated: Feb 4, 2026

Colorimetric Detection of Bacteria Using Litmus Test
Published on: September 17, 2016
CLEARED (Chemicals and Litmus testing with Effective Alkaline Range for Eye Damage): A Prospective, Interventional
Mark P Breazzano1,2,3, H Russell Day2, Sarah Tanaka2
1Department of Ophthalmology & Visual Sciences, Vanderbilt Eye Institute, Vanderbilt University Medical Center, Nashville, TN.
Objectives:
While immediate diagnosis and irrigation is standard chemical eye burn practice, it is unknown to what extent specific pH measurements influence management, given the frequent clinical availability of narrow-spectrum nitrazine pH strips. We hypothesize that exclusive broad-spectrum pH strip implementation leads to more accurate measurement and expedited ophthalmologic consultation.
Methods:
At a Level I trauma center over 25 months, all emergent adult ophthalmology consultations for chemical burns were included in a pre-intervention (n = 22) and post-intervention (n = 20) study design. During this time, narrow-spectrum nitrazine pH strips available to non-obstetric emergency department (ED) staff were exclusively replaced by broad-spectrum strips. Causative chemical, time from triage to ophthalmology consultation, examination findings, ocular pH by ED and ophthalmology staff, and irrigation quantity were analyzed.
Results:
Most burns were alkaline. Time from triage (p = 0.043) and irrigation quantity following consultation (p = 0.047) each decreased following exclusive ED implementation of broad-spectrum pH strips. There was greater pH congruence between consulting and primary physicians after intervention (p = 0.03).
Conclusions:
Exclusive non-obstetric implementation of broad-spectrum pH strips may allow greater accuracy and faster management of ocular chemical burns. Availability of narrow-spectrum pH strips may be dangerous clinically by falsely reassuring the examiner with inherent inaccuracy.
More Related Videos
10:38In Vivo Alkaline Comet Assay and Enzyme-modified Alkaline Comet Assay for Measuring DNA Strand Breaks and Oxidative DNA Damage in Rat Liver
Published on: May 4, 2016
04:32Sound Source Localization Testing in Single-sided Deafness Following Bone Conduction Intervention
Published on: December 20, 2024
Related Concept Videos
Effects of Chemicals: Overview
Inductive Effects on Chemical Shift: Overview
Ionic Strength: Effects on Chemical Equilibria
In this solution, the primary...
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
π Electron Effects on Chemical Shift: Overview