Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Echo01:06

Echo

974
The human ear cannot distinguish between two sources of sound if they happen to reach within a specific time interval, typically 0.1 seconds apart. More than this, and they are perceived as separate sources.
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
974
What is an Electrochemical Gradient?01:26

What is an Electrochemical Gradient?

127.9K
Adenosine triphosphate, or ATP, is considered the primary energy source in cells. However, energy can also be stored in the electrochemical gradient of an ion across the plasma membrane, which is determined by two factors: its chemical and electrical gradients.
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
127.9K
Weighted Mean00:57

Weighted Mean

6.4K
While taking the arithmetic, geometric, or harmonic mean of a sample data set, equal importance is assigned to all the data points. However, all the values may not always be equally important in some data sets. An intrinsic bias might make it more important to give more weightage to specific values over others.
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
6.4K
Atomic Weight01:25

Atomic Weight

13.5K
Protons and neutrons have approximately the same mass, about 1.67 × 10-24 grams. Scientists arbitrarily define this amount of mass as one atomic mass unit (amu) or one Dalton. Electrons are much smaller in mass than protons, weighing only 9.11 × 10-28 grams, or about 1/1800 of an atomic mass unit. As a result, they do not contribute much to an element's overall atomic mass. This means that, when considering atomic mass, it is customary to ignore the mass of any electrons and...
13.5K
Mass and Weight01:19

Mass and Weight

15.3K
Mass and weight are often used interchangeably in everyday conversation. For example,  medical records often show our weight in kilograms, but never in the correct units of newtons. In physics, however, there is an important distinction. Weight is the pull of the Earth on an object. It depends on the distance from the center of the Earth. Weight dramatically varies if we leave the Earth's surface, unlike mass, which does not vary with location. On the Moon, for example, the...
15.3K
Apparent Weight01:09

Apparent Weight

9.8K
True weight is the measure of the gravitational force acting on an object. However, if the object accelerates, its measured weight is different from its true weight. Similar observations can be made when the object is submerged in water. An object's weight in water is its apparent weight, which is equal to the difference between its true weight and the buoyant forces.
Consider a person standing on a bathroom scale inside an elevator. If the scale is accurate at rest, its reading equals the...
9.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Dosimetry and pharmacokinetics of [<sup>223</sup>Ra]Ra-dichloride alpha therapy in prostate cancer patients with bone metastases.

Physics in medicine and biology·2026
Same author

AI-augmented thyroid scintigraphy for robust classification of disease.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
Same author

Simultaneous partial volume correction and denoising of brain PET images, using transformers and transfer learning.

EJNMMI research·2026
Same author

FAP-Targeted Theranostics in Advanced Sarcoma: A Pilot Study of ⁶⁸Ga-FAPI-46 Imaging and ¹⁷⁷Lu-FAPI-2286 Therapy.

Clinical nuclear medicine·2026
Same author

Instrumentation Digital Twins in PET and SPECT Imaging: Current Status, Challenges, and Future Directions.

Computational and structural biotechnology journal·2026
Same author

Impact of partial volume correction on radiomics reproducibility in theranostic SPECT/CT imaging.

Medical physics·2026

Related Experiment Video

Updated: Feb 4, 2026

Gradient Echo Quantum Memory in Warm Atomic Vapor
10:00

Gradient Echo Quantum Memory in Warm Atomic Vapor

Published on: November 11, 2013

13.2K

Robust selective weighted field mapping using multi-echo gradient echo-based MRI.

Chemseddine Fatnassi1, Habib Zaidi1,2,3,4,5

  • 1Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva, Switzerland.

Physics in Medicine and Biology
|October 2, 2018
PubMed
Summary
This summary is machine-generated.

This study introduces a new method for generating accurate magnetic field maps in MRI, improving image quality by reducing distortions caused by air/tissue interfaces. The technique enhances field mapping in both high and low signal-to-noise ratio regions.

More Related Videos

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
05:07

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods

Published on: September 6, 2024

759
Echo Particle Image Velocimetry
16:31

Echo Particle Image Velocimetry

Published on: December 27, 2012

15.1K

Related Experiment Videos

Last Updated: Feb 4, 2026

Gradient Echo Quantum Memory in Warm Atomic Vapor
10:00

Gradient Echo Quantum Memory in Warm Atomic Vapor

Published on: November 11, 2013

13.2K
Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
05:07

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods

Published on: September 6, 2024

759
Echo Particle Image Velocimetry
16:31

Echo Particle Image Velocimetry

Published on: December 27, 2012

15.1K

Area of Science:

  • Medical Imaging
  • Biophysics
  • Magnetic Resonance Imaging

Background:

  • 3D gradient echo (GRE) and echo planar imaging (EPI) in MRI suffer from signal loss and image distortion at air/tissue interfaces due to macroscopic field gradients.
  • Conventional field mapping techniques often ignore magnitude data and struggle with noise and phase aliasing, especially at longer echo times (TE) and echo spacings (ΔTE).

Purpose of the Study:

  • To develop and validate a novel, noise-resilient method for computing accurate low and high-resolution magnetic field maps across all field map regimes (small and large echo spacing).
  • To improve the robustness of field mapping in challenging low signal-to-noise ratio (SNR) regions common in clinical MRI.

Main Methods:

  • An analytical approximation and a novel computational method were developed, weighting the field offset by magnitude signal decay quality to minimize noise dependence.
  • The method accommodates various echo time (TE) and echo spacing (ΔTE) regimes and complex phase wrap scenarios.
  • Performance was evaluated using simulated data, experimental phantoms, and in vivo human studies.

Main Results:

  • The proposed method significantly outperforms conventional techniques, especially in low SNR regions (e.g., near the sinus cavity, brain edges) with mean errors less than 1 Hz.
  • In high SNR regions (SNR > 20), it achieves comparable accuracy to conventional methods (mean error ~0.1 Hz).
  • The technique demonstrates enhanced robustness against noise and phase aliasing.

Conclusions:

  • The novel field mapping technique offers improved accuracy and robustness across diverse MRI acquisition parameters and SNR levels.
  • It shows significant promise for enhancing clinical MRI by providing better field map generation, particularly in challenging anatomical areas.
  • The method is easily implementable for rapid computation in clinical settings.