An actively shielded gradient coil design for use in planar MRI systems with limited space
Yaohui Wang1, Qiuliang Wang1, Lei Guo2
1Division of Superconducting Magnet Science and Technology, Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190, China.
Abstract:
In planar magnetic resonance imaging (MRI) systems, gradient coils are usually placed within a very limited space owing to the physical constraints of the small gap size (pole-pole) distance of the permanent magnet. Typically, the unshielded or partially shielded design scheme is adopted to generate required magnetic fields with reduced system costs. However, non-fully shielded coils can induce large eddy currents on the surrounding metal structures, including magnet poles, that significantly impact the imaging performance. This paper elaborates a new design strategy to resolve the limited space problem. Using the peripheral sections of the MRI system, a set of actively shielded gradient coils are purposefully designed. Between the two magnet poles, the actively shielded gradient coils occupy merely four coil layers (six coil layers are usually required), which offers an excellent shielding effect, thus reducing the image distortions. The saved space can be used to integrate a high-efficient cooling system. Moreover, the design scheme does not significantly increase the fabricating complexity.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Limiting Reactant
Structure-Activity Relationships and Drug Design
SAR studies the intricate relationship between a drug's chemical structure and biological activity. It focuses on understanding how modifications to a drug's structure can influence...
The Number e as a Limit
Space Trusses
At the core of a space truss lies the fundamental unit known as the tetrahedron. This structure is composed of six members that form a three-dimensional shape...