Resonance Frequency Analysis: Agreement and Correlation of Implant Stability Quotients Between Three Commercially
Purpose:
Purpose: The purpose of this study was to analyze the implant stability quotient (ISQ) values recorded by three commercially available resonance frequency analysis (RFA) instruments from a large cohort of implants in order to determine their accuracy and agreement with one another both for static measurements of ISQ at a given time and for change in ISQ over time.
Materials And Methods:
Materials and Methods: A cohort of n = 210 implants had their primary stability, secondary stability, or both evaluated in both the mesiodistal (MD) and buccolingual (BL) directions by means of ISQ using three different RFA instruments: Osstell ISQ (OISQ), Osstell IDx (OIDX), and the Penguin (PG). ISQ values were recorded both at the time of implant placement and at 3 months postinsertion prior to definitive restoration. All values were tabulated for a blinded statistical analysis using Bland-Altman plots to determine if the outcome values were in agreement both for primary and secondary stability. In addition, a subgroup was evaluated to determine if change in ISQ was also in agreement. An intraclass correlation (ICC) was used to measure the reliability of the measurements for each instrument.
Results:
Results: Bland-Altman plots confirmed that there was a high agreement for MD values between OISQ and OIDX, with 72.7% of readings being within one ISQ unit and 94.7% within four units. Comparing PG to OISQ, the respective values at one and four units were 15.3% and 82.3%, and comparing PG to OIDX, the respective values were 16.3% and 85.2%. In general, there was a greater uncertainty in the BL values having wider variability and demonstrating less agreement between instruments, with the percentage of readings falling within four units reducing to 85.9% (OISQ vs OIDX), 72.3% (PG vs OISQ), and 74.3% (PG vs OIDX). For change in ISQ over time, 92.3% of values were in agreement to within four units between instruments OISQ and OIDX in the MD direction and 73% in the BL direction. The respective percentage changes of values in agreement within four units for PG vs OISQ were 76.9% and 60.3% and for PG vs OIDX were 80% and 53.8%. The paired t test from mixed effects revealed that there was a significant difference for mean MD values between PG vs OISQ; P = .015 with a mean 0.823 units higher was recorded for PG. Similarly for PG vs OIDX, P = .008 with a mean 0.871 units higher was recorded for PG. For mean BL values between PG vs OIDX, P = .000 with a mean 1.161 units higher was recorded for PG, and finally, for OISQ vs OIDX, P = .005 with a mean 0.597 units higher was recorded for OISQ. However, the maximum upper and lower bound estimated bias between any two instruments was only 1.86 units and 0.46 units both for PG vs OIDX in the BL direction, and it is doubtful that this is of clinical relevance even if statistically significant. ICC revealed that for static MD measurements, there was an 85% reliability between all three instruments (range: 79% to 97%). For BL measurements, the reliability value was 66% (range: 69% to 71%). When considering ICC for changes in ISQ values over time in the MD direction, there was a 70% reliability between all three instruments (range: 58% to 94%). For BL measurements, the reliability value was 58% (range: 46% to 91%).
Conclusion:
Conclusion: Differences exist between instruments to some extent, most notably between the Penguin and the two instruments from Osstell, which showed good agreement to each other. While differences in evaluating ISQ with the PG were statistically significant, they were less than 1.86 units at the upper bound limit, and it is doubtful that this is of clinical relevance. Increased variability and reduced reliability for BL values render these less clinically sound when trying to assess primary stability.
More Related Videos
08:22Calibration-free In Vitro Quantification of Protein Homo-oligomerization Using Commercial Instrumentation and Free, Open Source Brightness Analysis Software
Published on: July 17, 2018
10:35Composition and Properties of Aquafaba: Water Recovered from Commercially Canned Chickpeas
Published on: February 10, 2018
Related Concept Videos
Reaction Quotient
The Quotient Rule
Resonance
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if: