Related Experiment Video
Updated: Feb 4, 2026

Sample Preparation for Probe Electrospray Ionization Mass Spectrometry
Published on: February 19, 2020
Analyte-substrate interactions at functionalized tip electrospray ionization mass spectrometry: Molecular mechanisms
Ya-Nan Yao1, Bin Hu1,2
1Institute of Mass Spectrometer and Atmospheric Environment, Jinan University, Guangzhou, 510632, China.
Abstract:
Conventional electrospray ionization mass spectrometry (ESI-MS) commonly uses capillary tip for sample introduction and ionization. In recent years, ESI-MS using noncapillary substrate tips has attracted growing interest as it allows separation and enrichment of analytes from complex samples due to analytes-substrate interactions. In this work, model mixtures and functionalized tips were employed to investigate the molecular mechanism of the analyte-substrate interactions. The mixtures were directly loaded on substrate tips, and then temporal responses of analytes were investigated by monitoring selected ion chromatogram (SIC) responses of each analyte. It is found that all analytes are sprayed out together when bulk solution loaded substrate surface and then sequential ionization of analytes were observed. Sequential ionization of analytes was affected by the analytes-substrate interactions which caused analytes of weaker-interaction to be faster moved and the analytes of stronger-interactions to be retained on the substrate. The main molecular mechanisms of analyte-substrate interactions were revealed to be hydrophobic interactions and electrostatic interactions. Furthermore, based on the mechanistic insights, functionalized tips were further applied for rapid extractive sampling of target analytes from complex samples with good analytical performances. Overall, this study on the mechanism and applications of analyte-substrate interactions is useful for understanding the fundamental principles and further developments of functionalized tip electrospray ionization (TESI).
More Related Videos
12:59A Study of the Complexation of MercuryII with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry
Published on: January 8, 2016
09:18Time-resolved ElectroSpray Ionization Hydrogen-deuterium Exchange Mass Spectrometry for Studying Protein Structure and Dynamics
Published on: April 17, 2017
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Molecular Fragmentation Overview
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can occur at...
Mechanical Protein Functions
Ionization Energy
Mass Spectrometry: Overview