Related Experiment Video
Updated: Feb 3, 2026

Stereotactic Radiosurgery for Gynecologic Cancer
Published on: April 17, 2012
Cone-Beam CT image contrast and attenuation-map linearity improvement (CALI) for brain stereotactic radiosurgery
SayedMasoud Hashemi1, Christopher Huynh2, Arjun Sahgal1
1Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON, Canada.
Abstract:
A Contrast and Attenuation-map Linearity Improvement (CALI) framework is proposed for cone-beam CT (CBCT) images used for brain stereotactic radiosurgery (SRS). The proposed framework is tailored to improve soft tissue contrast of a new point-of-care image-guided SRS system that employs a challenging half cone beam geometry, but can be readily reproduced on any CBCT platform. CALI includes a pre- and post-processing step. In pre-processing we apply a shading and beam hardening artifact correction to the projections, and in post-processing step we correct the dome/capping artifact on reconstructed images caused by the spatial variations in X-ray energy generated by the bowtie-filter. The shading reduction together with the beam hardening and dome artifact correction algorithms aim to improve the linearity and accuracy of the CT-numbers (CT#). The CALI framework was evaluated using CatPhan to quantify linearity, contrast-to-noise (CNR), and CT# accuracy, as well as subjectively on patient images acquired on a clinical system. Linearity of the reconstructed attenuation-map was improved from 0.80 to 0.95. The CT# mean absolute measurement error was reduced from 76.1 to 26.9 HU. The CNR of the acrylic insert in the sensitometry module was improved from 1.8 to 7.8. The resulting clinical brain images showed substantial improvements in soft tissue contrast visibility, revealing structures such as ventricles which were otherwise undetectable in the original clinical images obtained from the system. The proposed reconstruction framework also improved CT# accuracy compared to the original images acquired on the system. For frameless image-guided SRS, improving soft tissue visibility can facilitate evaluation of MR to CBCT co-registration. Moreover, more accurate CT# may enable the use of CBCT for daily dose delivery measurements.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...