Intermittent Pneumatic Compression Dosage for Adults and Children with Lymphedema: A Systematic Review
J Jane Phillips1,2, Susan J Gordon1
11 College of Nursing and Health Sciences, Flinders University, Adelaide, Australia.
Lymphatic Research and Biology
|October 20, 2018
Summary
Intermittent pneumatic compression (IPC) for lymphedema (LE) shows best results with 45-60 minute sessions at 30-60 mmHg. Evidence for specific dosages in children or limb differences remains limited.
Area of Science:
- Medical Science
- Rehabilitation Medicine
- Vascular Health
Background:
- Pneumatic compression therapy has been utilized for lymphedema (LE) management for over four decades.
- Optimal treatment parameters and dosage for intermittent pneumatic compression (IPC) lack established consensus.
- Evolution of IPC application modes necessitates a review of current evidence.
Purpose of the Study:
- To systematically review and report evidence on the dosage of intermittent pneumatic compression (IPC) for lymphedema (LE).
- To specifically analyze dosage differences for upper versus lower limbs.
- To compare pediatric versus adult dosage recommendations for IPC in LE management.
Main Methods:
- Comprehensive literature search across Medline, Embase, CINAHL, PubMed, and Scopus for studies on LE and IPC devices.
- Inclusion of reference lists from identified articles.
- Systematic review registration (PROSPERO ID: CRD42017054338) and adherence to PRISMA guidelines.
- Exclusion of non-English, non-human, physiological outcome, or combination therapy studies.
- Quality appraisal using the McMaster University Critical Review Tool by multiple researchers.
Main Results:
- Sixteen studies met inclusion criteria; four were analyzed separately due to concurrent compression garment use.
- One randomized controlled trial achieved Level II evidence; others were Level III-2 or below.
- Recent trends show multichamber sleeve devices using lower pressures and shorter treatment times.
- Limited evidence exists for specific IPC dosages for pediatric populations or particular limbs.
- Newer devices with lower pressures facilitate home use and self-management of LE.
Conclusions:
- Moderate quality, low-level evidence suggests optimal outcomes with sequential IPC programs using pressures of 30-60 mmHg for 45-60 minutes.
- Methodological limitations across the included studies necessitate cautious interpretation of findings.
- Further high-quality research is needed to establish definitive IPC dosage guidelines for lymphedema.
Related Concept Videos
Dosage Regimen: Multiple Oral Dosage
255
Understanding how a drug's concentration fluctuates within the body over time is crucial in pharmacokinetics, particularly with multiple oral doses. A graphical representation of multiple oral dosages provides insight into these dynamics. Typical accumulation curves of a drug's concentration in the body reveal a sawtooth pattern, indicating periodic peaks and troughs correlating with each dose administration and the drug's subsequent elimination.The plasma concentration at any time during an...
255
Dosage Compensation
7.4K
In animals, gender is determined by the number and type of sex chromosome. For example, human females have two X chromosomes, and males have one X and one Y chromosome, whereas C.elegans with one X chromosome is a male, and the one with two X chromosomes is a hermaphrodite.
In addition to sexual development, the X chromosome has genes involved in autosomal functions such as brain development and the immune system. Therefore, males and females with distinct numbers of X chromosomes will...
In addition to sexual development, the X chromosome has genes involved in autosomal functions such as brain development and the immune system. Therefore, males and females with distinct numbers of X chromosomes will...
7.4K
Review and Preview
8.4K
In statistics, several tools are used to interpret the data. Measures of central tendency represent the characteristics of the data, such as mean, median, and mode. Additionally, measures of variance like standard deviation and range are used to find the spread of data from the mean. Relative standing measures the distance between data locations. Commonly used measures of relative standings are percentile, z score, and quartiles.
Percentiles are a type of fractile that partition data into...
Percentiles are a type of fractile that partition data into...
8.4K
Review and Preview
11.3K
Data are individual items of information obtained from a population or sample. Data may be classified as qualitative (categorical), quantitative continuous, or quantitative discrete. Because it is not practical to measure the entire population in a study, researchers use samples to represent the population. A random sample is a representative group from the population chosen by using a method that gives each individual in the population an equal chance of being included in the sample. Random...
11.3K
Dosage Regimen: Individualization
184
Individualization in dosing regimens is the customization of medication doses for individual patients. Its necessity arises from the goal of maximizing therapeutic benefits while minimizing risks. This approach is pivotal because human responses to drugs can vary widely; what is effective for one person may be inadequate or excessive for another. Interpatient (intersubject) variability refers to differences in drug responses between individuals, while intrapatient (intrasubject) variability...
184
Random and Systematic Errors
14.9K
Scientists always try their best to record measurements with the utmost accuracy and precision. However, sometimes errors do occur. These errors can be random or systematic. Random errors are observed due to the inconsistency or fluctuation in the measurement process, or variations in the quantity itself that is being measured. Such errors fluctuate from being greater than or less than the true value in repeated measurements. Consider a scientist measuring the length of an earthworm using a...
14.9K