Iron-Containing Abdominal Pathologies: Exploiting Magnetic Susceptibility Artifact on Dual-Echo Gradient-Echo
Aaron J Thomas, Ajaykumar C Morani1, Peter S Liu2
1Department of Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX.
Abstract:
A multitude of pathologic entities involve abnormal iron deposition in the abdomen. These lesions demonstrate decreased signal on longer magnetic resonance sequences with longer echo time due to T2* effect. Dual-echo gradient-echo sequences demonstrate increased susceptibility artifact with longer echo sequences. In this article, the spectrum of iron-containing abdominal pathologies is illustrated, with their characteristic distributions. Included is a brief discussion of the physics of magnetic resonance imaging of iron-containing lesions.
Insights
Abnormal abdominal iron deposition causes decreased MRI signal on longer echo times due to T2* effects. This review illustrates iron-containing pathologies and their distributions, discussing MRI physics.
Area of Science:
- Radiology
- Medical Imaging
- Pathology
Background:
- Abnormal iron deposition is a feature of various abdominal pathologies.
- Magnetic Resonance Imaging (MRI) is crucial for diagnosing these conditions.
- Understanding iron's effect on MRI signals is key for accurate interpretation.
Purpose of the Study:
- To illustrate the spectrum of abdominal pathologies with abnormal iron deposition.
- To describe the characteristic imaging distributions of these iron-laden lesions.
- To provide a brief overview of the physics behind MRI of iron-containing tissues.
Main Methods:
- Review of abdominal pathologies involving abnormal iron deposition.
- Illustration of characteristic imaging findings on MRI, particularly T2* effects.
- Discussion of dual-echo gradient-echo sequences and susceptibility artifacts.
Main Results:
- Iron deposition in abdominal lesions leads to decreased signal intensity on longer echo time sequences (T2* effect).
- Increased susceptibility artifact is observed with longer echo sequences in dual-echo gradient-echo imaging.
- Characteristic distributions aid in identifying specific iron-containing pathologies.
Conclusions:
- Abnormal iron deposition significantly impacts MRI signal characteristics.
- Recognizing T2* effects and susceptibility artifacts is vital for diagnosing iron-related abdominal conditions.
- This review provides a guide to the MRI appearance and distribution of iron-containing abdominal pathologies.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Magnetic Resonance Imaging
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Imaging Studies IV: Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...