Related Experiment Video
Updated: Feb 3, 2026

Preparation of Mitochondria from Ovarian Cancer Tissues and Control Ovarian Tissues for Quantitative Proteomics Analysis
Published on: November 18, 2019
iTRAQ-Based Quantitative Proteomic Analysis Reveals Changes in Metabolite Biosynthesis in Monascus purpureus in
Jialan Zhang1, Yingbao Liu2, Li Li3
1College of Animal Science, Yangtze University, Jingzhou 434025, China. zhangjl@yangtzeu.edu.cn.
Background:
Low-frequency magnetic fields (LF-MFs) dampen the citrinin output by Monascus purpureus in fermentations. The influence of LF-MFs on biosynthesis by M. purpureus was evaluated at the protein level.
Methods:
Cultures were treated with a 1.6-mT MF from day 0 to day 2 of incubation, and secondary metabolite production was evaluated on the day 12 of incubation. All proteins were extracted from M. purpureus mycelia and subjected to isobaric tags for relative and absolute quantification (iTRAQ) labeling and subsequent liquid chromatography/mass spectrometry (LC-MS/MS) analysis on day 6 of fermentation.
Results:
There was no difference in biomass between the treated samples and the control. Citrinin production was 46.7% lower, and the yields of monacolin K and yellow, orange, and red pigment were 29.3%, 31.3%, 41.7%, and 40.3% higher, respectively, in the exposed samples compared to the control. Protein expression in M. purpureus under LF-MF treatment was quantified using iTRAQ technology. Of 2031 detected proteins, 205 were differentially expressed. The differentially-expressed proteins were subjected to Gene Ontology (GO) functional annotation and statistical analysis, which revealed that they mainly refer to biological metabolism, translation, antioxidant, transport and defense pathways. Among all the tagged proteins, emphasis was placed on the analysis of those involved in the synthesis of citrinin, pigment and monacolin K was emphasized.
Conclusions:
LF-MFs affected Monascus secondary metabolism at the protein level, and aggregate data for all the protein profiles in LF-MF-treated Monascus was obtained.
Related Concept Videos
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Frequency Response of BJT
Low-Frequency Response: At low frequencies, the behavior of the BJT is determined by its DC bias point, which is set by the...
Frequency Response of a Circuit
The transfer function is pivotal in characterizing how these circuits react to various frequencies, facilitating a profound understanding of their behavior. An essential parameter is the time constant, signifying the...
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules:
Energy In A Magnetic Field
Take an ideal inductor with zero resistance. Although it's practically impossible, assume that the coil's resistance is so small that it is practically negligible. The loss of the field's energy to dissipate thermal energy (or heat) is thus...

