Related Experiment Video
Updated: Feb 3, 2026

Simulator Training for Endovascular Neurosurgery
Published on: May 6, 2020
The real-time ultrasonography for fusion image in glioma neurosugery
Dong-Fang Wu1, Wen He1, Song Lin2
1Department of Ultrasound, Beijing Tian tan Hospital, Capital Medical University, 6 Tiantan Xi Li, Dong Cheng District, Beijing, 100050, China.
Objectives:
The aim of study is to evaluate the general performance and efficiency of the using real time intraoperative ultrasound system with Volume Navigation system technology in glioma. Compare glioma intraoperative ultrasound and contrast agent ultrasound images to obtained preoperative MRI with fusion image in a real-time.
Patients And Methods:
Fifteen patients had been performed fusion imaging involved intraoperative real-time ultrasound and contrast agent ultrasound with preoperative MR imaging including preoperative gadolinium-enhanced MRI from March 2017 to December 2017. The number of tumor was counted online fusion imaging in real time ultrasound with and without preoperative MR. We analyzed ultrasound coplanar MR modalities in real time including tumor location, margin (obscure or defined). In addition, intraoperative ultrasound enhancement pattern was analyzed compare it to preoperative reconstruction gadolinium-enhanced T1-weighted MRI. Two radiologists who made planning ultrasound assessment for the focus lesion based on a 4 scoring system according to the degree of confidence.
Results:
Thirteen of fifteen patients whose automatically registration successful intraoperative neurosurgery accepted preoperative MR examination. Seven of fifteen fine-tuning registration phase were performed and satisfactory with fusion image substantially. Intraoperatively, 73.3% (11/15) glioma nodules were definite on conventional B-mode US by a radiologist who doesn't know the MR result before fusion US with MRI. However, 100% tumors were detected on fusion B-mode ultrasound imaging with MRI. Two radiologists evaluated the score between fusion B-mode ultrasound and CEUS with coplanar MRI and had a result that score was upgraded in 69.2% (9/13) and 84.6% (11/13) patients. Inter-observer agreement was significant (kappa value = 1.0, p < 0.001) in B-mode ultrasound fusion image with MRI. Inter-observer agreement was moderate (kappa value = 0. 0.618, p < 0.001) in CEUS fusion image with MRI.
Conclusion:
Fusion imaging is very useful to detect poor sonographic visibility tumor on fusion B-mode US imaging with MR images. Fusion image may demonstrate multiplane images including same standard and nonstandard MRI and US images to help localize tumor. The additional real time fusion CEUS mode image with MR is a safe method for neurosurgery and the use of CEUS should be considered when fusion B-mode ultrasound imaging alone is not satisfactory for margin.
Related Concept Videos
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Tagging and Fusion Proteins

