Related Experiment Video
Updated: Feb 3, 2026

Measuring the Time-Evolution of Nanoscale Materials with Stopped-Flow and Small-Angle Neutron Scattering
Published on: August 6, 2021
In-phantom neutron dose measurement using Gafchromic film dosimeter for QA of BNCT beams
Ming-Chen Hsiao1, Shiang-Huei Jiang1
1Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC.
Abstract:
In order to improve the quality assurance (QA) procedure for beams of boron neutron capture therapy (BNCT), this study introduced using the Gafchromic film dosimeter for neutron dose measurement of BNCT beams. The crucial part of this study was investigating an approach to employ the Gafchromic film dosimeter placed inside a PMMA phantom irradiated by a BNCT beam. The spatial distribution of neutron dose of the film was determined using measurements and Monte Carlo calculations. By employing the present approach, the two-dimensional distributions of the neutron dose component of the film at specific depths in the phantom were successfully obtained. The determined neutron dose profiles were in good agreement with the calculated ones. This study also confirmed the finding that the film dosimeter is sensitive to thermal neutrons by comparing the depth-capture-reaction-rate and depth-dose distributions. Results of this work not only proved the feasibility of using the proposed method for the QA measurement of beam delivery but also revealed the advantages of easy-handling and remarkable spatial resolution of the film dosimeter when applied to BNCT fields. The present work can help to verify the dose uniformity and output stability of BNCT beams prior to clinical irradiation.
Related Concept Videos
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...

