Heavy-tailed prior distributions for sequence count data: removing the noise and preserving large differences

Anqi Zhu1, Joseph G Ibrahim1, Michael I Love1,2

  • 1Department of Biostatistics, University of North Carolina-Chapel Hill, NC, USA.

Summary

This study introduces apeglm, a novel method for RNA-seq analysis that uses a Cauchy prior to improve the estimation of gene expression changes. Apeglm reduces bias and variance in logarithmic fold change estimates, enhancing differential expression analysis.

Related Concept Videos

Data: Types and Distribution01:19

Data: Types and Distribution

In biostatistics, data are the observations collected for analysis. There are two main types: parametric and non-parametric. Parametric data, which include continuous (e.g., weight) and discrete numerical data (e.g., number of tablets), assume a particular distribution pattern, often the normal distribution. Non-parametric data do not adhere to a specific distribution and typically comprise nominal (e.g., gender) and ordinal categorical data (e.g., pain scale ratings).
Distributions in...
1.8K
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models01:06

Model Approaches for Pharmacokinetic Data: Distributed Parameter Models

Pharmacokinetic models are mathematical constructs that represent and predict the time course of drug concentrations in the body, providing meaningful pharmacokinetic parameters. These models are categorized into compartment, physiological, and distributed parameter models.
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
249
Electric Potential and Potential Difference01:16

Electric Potential and Potential Difference

Suppose a positive test charge moves away from a positive static charge, then the Coulomb force does positive work, and its electric potential energy decreases. The potential energy per unit charge is defined as the electric potential. The electric potential is independent of the test charge.
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
5.7K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.3K
Identifying Statistically Significant Differences: The F-Test01:14

Identifying Statistically Significant Differences: The F-Test

The F-test is used to compare two sample variances to each other or compare the sample variance to the population variance. It is used to decide whether an indeterminate error can explain the difference in their values. The underlying assumptions that allow the use of the F-test include the data set or sets are normally distributed, and the data sets are independent of each other. The test statistic F is calculated by dividing one variance by another. In other words, the square of one standard...
3.8K
Sum and Difference OpAmps01:22

Sum and Difference OpAmps

Operational amplifiers (op-amps) are versatile devices that extend beyond amplification. In this context, two specific op-amp configurations are explored: the summing and difference amplifiers.
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...
1.4K