Methods to monitor accurate and consistent electrode placements in conventional transcranial electrical stimulation
Aprinda Indahlastari1, Alejandro Albizu1, Nicole R Nissim1
1Department of Clinical and Health Psychology, Department of Neuroscience, Center for Cognitive Aging and Memory, McKnight Brain Institute, University of Florida, Gainesville, FL, USA.
Background:
Inaccurate electrode placement and electrode drift during a transcranial electrical stimulation (tES) session have been shown to alter predicted field distributions in the brain and thus may contribute to a large variation in tES study outcomes. Currently, there is no objective and independent measure to quantify electrode placement accuracy/drift in tES clinical studies.
Objective/Hypothesis:
We proposed and tested novel methods to quantify accurate and consistent electrode placements in tES using models generated from a 3D scanner.
Methods:
Accurate electrode placements were quantified as Discrepancy in eight tES participants by comparing landmark distances of physical electrode locations F3/F4 to their model counterparts. Distances in models were computed using curve and linear based methods. Variability of landmark locations in a single subject was computed for multiple stimulation sessions to determine consistent electrode placements across four experimenters.
Main Results:
We obtained an average of 0.4 cm in Discrepancy, which was within the placement accuracy/drift threshold (1 cm) for conventional tES electrodes (∼35 cm2) to achieve reliable tES sessions suggested in the literature. Averaged Variability was 5.2%, with F4 electrode location as the least consistent placement.
Conclusions:
These methods provide objective feedback for experimenters on their performance in placing tES electrodes. Applications of these methods can be used to monitor electrode locations in tES studies of a larger cohort using F3/F4 montage and other conventional electrode arrangements. Future studies may include co-registering the landmark locations with imaging-derived head models to quantify the effects of electrode accuracy/drift on predicted field distributions in the brain.
More Related Videos
07:47Personalized 3D-printed Headgear for Multi-electrode Transcranial Electrical Stimulation
Published on: September 9, 2025
10:11Updated Technique for Reliable, Easy, and Tolerated Transcranial Electrical Stimulation Including Transcranial Direct Current Stimulation
Published on: January 3, 2020
Related Concept Videos
Standard Electrode Potentials
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Enolate Mechanism Conventions
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Therapeutic Drug Monitoring: Drug Analysis Methods
Self-Presentation: Self-Monitoring and Self-Handicapping