Related Experiment Video
Updated: Feb 2, 2026

Postoperative Ileus Murine Model
Published on: July 12, 2024
New insertion method of transnasal ileus tube for small bowel obstruction: Anterior balloon method
Daisuke Yamaguchi1,2, Kei Ikeda1, Yuki Takeuchi1
1Department of Gastroenterology, National Hospital Organization Ureshino Medical Center, Ureshino, Japan.
Background:
Small bowel obstruction (SBO) is usually caused by postoperative adhesions and malignant disease, and decompression is effective for SBO. Our previous case report suggested that a new transnasal ileus tube insertion method, the anterior balloon method (ABM), could achieve decompression for adhesive SBO.
Aims:
The study aimed to investigate the effectiveness of a new method for inserting transnasal ileus tubes in patients with SBO.
Methods:
Altogether, 134 patients with small bowel obstruction treated from January 2011 to December 2017 were reviewed. The patients were categorized into two groups: those with the new method that inserts an anterior balloon (ABM group: 52 patients, 2014-2017) versus those with the ordinary insertion method (OIM group: 82 patients, 2011-2014).
Results:
The patients' characteristics and symptoms on admission were similar in the ABM and OIM groups. Adhesions were the main cause of ileus in the two groups. The insertion time duration was significantly shorter in the ABM group than in OIM group (28.4 ± 9.1 vs. 33.5 ± 13.0 min; p = 0.01). The ABM group also had significantly longer tubes than OIM group (222.4 ± 32.2 vs. 157.4 ± 31.7 cm; p < 0.001), which resulted in a significantly shorter time until clinical symptoms were relieved in ABM group. There were no significant differences in adverse events between the two groups.
Conclusions:
The ABM group had shorter insertion duration and longer tubes than those of OIM group. The ABM might become a preferred therapeutic choice to achieve decompression in patients with SBO.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
The Scientific Method
The Scientific Method
Generally, predictions are tested using carefully-designed experiments. Based on the outcome of these...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Newton’s Method
Decision Making: P-value Method
First, a specific claim about the population parameter is proposed. The claim is based on the research question and is stated in a simple form. Further, an opposing statement to the claim is also stated. These statements can act as null and alternative hypotheses: a null hypothesis would be a neutral statement while the alternative hypothesis can...

