Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
Published on: July 15, 2009
Dynamic alignment using external socket reaction moments in trans-tibial amputees
N Jonkergouw1, M R Prins2, P van der Wurff3
1Orthopedie Techniek Aardenburg, Military Rehabilitation Centre Aardenburg, Doorn, The Netherlands; Department of Research and Development, Military Rehabilitation Centre Aardenburg, Doorn, The Netherlands; Department of Human Movement Sciences, Faculty of Behavioral and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, The Netherlands; Department of Biomedical Engineering, Faculty of Biomechanical Engineering, University of Strathclyde, Glasgow, Scotland, United Kingdom.
Background:
Prosthetic alignment is used to optimize prosthetic functioning and comfort. Spatio-temporal and kinematic gait parameters are generally observed to guide this process. However, they have been shown to be influenced by compensations, which reduces their sensitivity to changes in alignment. Alternatively, the use of moments working at the base of the prosthetic socket, external socket reaction moments (ESRM), has been proposed to quantify prosthetic alignment.
Research Question:
To investigate if a predetermined kinetic alignment criterion, 0Nm averaged over the stance phase, can be used to fine-tune prosthetic alignment.
Methods:
10 transtibial amputees were included in this intervention study. Firstly, their prostheses were aligned using conventional alignment procedures. Kinetic parameters and Socket Comfort Score (SCS) were measured in this initial alignment (IA) condition. Subsequently, the coronal plane ESRM during gait was presented to the prosthetist in real time using a Gait Real-time Analysis Interactive Lab. The prosthetist iteratively adapted the prosthetic alignment towards a predetermined average ESRM during the stance phase of 0 Nm. At the Final Alignment (FA), kinetic parameters and SCS were measured again and a paired sample t-test was performed to compare ESRMs and SCSs between alignments.
Results:
A significant (p < 0.001) change was found in the absolute coronal plane ESRM (mean ± SD) from IA (|0.104| ± 0.058 Nm/kg) to FA (|0.012| ± 0.015 Nm/kg). In addition a significant (p < 0.001) change of the external coronal adduction knee moments was observed from IA (-0,127 ± 0.079 Nm/kg) to FA (-0.055 ± 0.089 Nm/kg), however this change was more variable among participants. On average, no significant (p = 0.37) change in the SCS was observed.
Significance:
While this study shows the potential of quantifying and guiding alignment with the assistance of kinetic criteria, it also suggests that a sole reliance on the ESRM as a single alignment criterion might be too simple.
More Related Videos
08:08Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis
Published on: May 8, 2014
08:36Dynamic Inter-subject Functional Connectivity Reveals Moment-to-Moment Brain Network Configurations Driven by Continuous or Communication Paradigms
Published on: March 21, 2019
Related Concept Videos
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...
Dynamic Equilibrium
Moment of Inertia
If a rigid body is rotating about an axis but is not in translational motion, its translational kinetic energy is zero. However, since each particle undergoes rotational motion, it possesses non-zero velocity and kinetic energy. Thus, the kinetic energy of the rigid body, which is the sum of the...
Principal Moments of Area
The principal moment of inertia axes are the...
Moment-Area Theorems
The theorem is divided into two parts. The first part connects the angle between tangents at any two points on the beam's elastic curve to the area under a curve derived by...
Bond Polarity, Dipole Moment, and Percent Ionic Character