Related Experiment Video
Updated: Feb 2, 2026

Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
Confined Concrete in Fiber-Reinforced Polymer Partially Wrapped Square Columns: Axial Compressive Behavior and Strain
Yong-Chang Guo1, Shu-Hua Xiao2, Jun-Wei Luo3
1School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou 510006, China. guoyc@gdut.edu.cn.
This study investigates concrete columns strengthened with fiber-reinforced polymer (FRP) strips. A new model accurately predicts the behavior of partially wrapped columns, improving structural analysis and design.
Area of Science:
- Civil Engineering
- Materials Science
Background:
- Reinforced concrete (RC) columns are often strengthened using fiber-reinforced polymer (FRP) strips.
- Partial wrapping strengthening technique (PWST) is common, but the confinement mechanism is less understood than full wrapping (FWST).
Purpose of the Study:
- To experimentally investigate the behavior of confined concrete in FRP partially wrapped square columns under axial compression.
- To evaluate the effects of FRP strip width and thickness on stress-strain behavior.
- To develop and validate a new design-oriented stress-strain model for these columns.
Main Methods:
- Experimental investigation of FRP partially wrapped square columns under axial compression.
- Utilized particle image velocimetry (PIV) for non-contact strain measurement.
- Compared experimental results with existing design-oriented stress-strain models.
Main Results:
- Axial and hoop strains were larger at the mid-plane of adjacent FRP strips compared to the mid-plane of individual strips.
- Significant variation in hoop strains was observed along the column height.
- Existing models showed limitations in predicting the behavior of partially wrapped columns.
Conclusions:
- The study provides crucial insights into the confinement mechanism of FRP partially wrapped columns.
- A new design-oriented stress-strain model was proposed and validated.
- The proposed model demonstrates superior accuracy compared to existing models for FRP partially wrapped square columns.