Related Experiment Video
Updated: Feb 1, 2026

Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α
Published on: June 14, 2018
Monitoring Disease Activity in Systemic Lupus Erythematosus With Single-Molecule Array Digital Enzyme-Linked
Alexis Mathian1, Suzanne Mouries-Martin2, Karim Dorgham3
1Sorbonne Université, Assistance Publique-Hôpitaux de Paris, Groupement Hospitalier Pitié-Salpêtrière, French National Referral Center for Systemic Lupus Erythematosus, Antiphospholipid Antibody Syndrome and Other Autoimmune Disorders, Service de Médecine Interne 2, Institut E3M, Inserm UMRS, Centre d'Immunologie et des Maladies Infectieuses (CIMI-Paris), Paris, France.
Objective:
No simple or standardized assay is available to quantify interferon-α (IFNα) in routine clinical practice. Single-molecule array (Simoa) digital enzyme-linked immunosorbent assay (ELISA) technology enables direct IFNα quantification at attomolar (femtogram per milliliter [fg/ml]) concentrations. This study was undertaken to assess IFNα digital ELISA diagnostic performances to monitor systemic lupus erythematosus (SLE) activity.
Methods:
IFNα concentrations in serum samples from 150 consecutive SLE patients in a cross-sectional study were determined with digital ELISA and a functional biologic activity assay (bioassay). According to their Safety of Estrogens in Lupus Erythematosus National Assessment version of the Systemic Lupus Erythematosus Disease Activity Index (SLEDAI) flare composite scores, patients were divided into groups with inactive SLE (SLEDAI score of <4 or clinical SLEDAI score of 0) or active SLE (SLEDAI score of ≥4 or clinical SLEDAI score of >0), and into groups with no flare or mild/moderate flare or severe flare.
Results:
Based on serum samples from healthy blood donors, the abnormal serum IFNα level threshold value was 136 fg/ml. Next, using receiver operating characteristic curves for an SLE patient series that was widely heterogeneous in terms of disease activity and organ involvement, the threshold IFNα value associated with active disease was determined to be 266 fg/ml. The digital ELISA-assessed serum IFNα level was a better biomarker of disease activity than the Farr assay because its specificity, likelihood ratio for positive results, and positive predictive value better discerned active SLE or flare from inactive disease. The digital ELISA was more sensitive than the bioassay for detecting low-abnormal serum IFNα concentrations and identifying patients with low disease activity.
Conclusion:
Direct serum IFNα determination with a highly sensitive assay might improve monitoring of clinical SLE activity and selection of the best candidates for anti-IFNα treatment.
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Enzyme-linked Receptors
Neurotrophin (NT) receptors are a family of RTKs, including trkA, trkB, and trkC (tropomyosin-related kinase) receptors. TrkA is specific for nerve growth factor (NGF), neurotrophin-6, and neurotrophin-7. TrkB binds...
Covalently Linked Protein Regulators
These groups modify specific amino acids in a protein....
Transducer Mechanism: Enzyme-Linked Receptors
Major types that are helpful drug targets include:
Enzymes and Activation Energy
Enzymes
Enzyme deficiencies can often translate into life-threatening diseases. For example, a genetic abnormality resulting in the deficiency of the enzyme G6PD...