Related Experiment Video
Updated: Feb 1, 2026

Author Spotlight: Advancing Pathogen Diagnostics with Standardized LAMP
Published on: September 8, 2023
Detection of Mycoplasma Contamination of Cell Culture by A Loop-Mediated Isothermal Amplification Method
Zohre Soheily1, Mohammad Soleimani1,2, Keivan Majidzadeh-Ardebili3,4
1Department of Microbiology, Qom Branch, Islamic Azad University, Qom, Iran.
Objective:
Mycoplasmas are major contaminants of cell culture and affect in vitro biological and diagnostic tests. Mycoplasma detection is conducted using culture and molecular methods. These methods vary in terms of accuracy, reliably and sensitivity. Loop-mediated isothermal amplification (LAMP) is used to amplify target DNA in a highly specific and rapid manner. This study aimed to develop a LAMP method for rapid detection of Mycoplasma in culture samples.
Materials And Methods:
In this descriptive laboratory study, for LAMP detection of Mycoplasma contaminations in cell culture, we used primers specifically designed for targeting the 16S rRNA conserved gene of Mycoplasma spp. For a positive control structure, 16S rRNA amplified based on PCR, was cloned in a plasmid vector and sequenced. The assay specificity was evaluated using Mycoplasma genomic DNA and a panel containing genomes of gram-positive and gram-negative organisms.
Results:
In this study, the method developed for detection of Mycoplasma contamination of cell cultures was a rapid, sensitive and cost-effective LAMP approach. The results demonstrated that this method benefits from high specificity (100%) for amplification of Mycoplasma strains and high speed (multiplication within 60 minutes), while it does not require expensive laboratory equipment compared to those needed for polymerase chain reaction (PCR)-based detection.
Conclusion:
Our study is the first report about application of LAMP assay based on 16S rRNA gene for detection of Mycoplasma strains; this technique could be considered a useful tool for rapid detection of contamination of cell culture.
Related Concept Videos
Isothermal Processes
An ideal gas can also undergo isothermal expansion or compression.
For example, consider 1 mole of an ideal gas inside an isolated cylinder at initial volume V...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Cell Signaling Feedback Loops
Negative feedback loops
Most signaling systems have negative feedback loops that can perform different functions such as output limiter, and adaptation.
Output limiter
Upon receiving an input signal, the cellular response rapidly increases until a threshold is reached. Beyond this threshold, a negative feedback loop...
Feedback Loops
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
RACE - Rapid Amplification of cDNA Ends

