Intraoperative near-infrared imaging with receptor-specific versus passive delivery of fluorescent agents in

Steve S Cho1,2, Jun Jeon1,2, Love Buch1

  • 1Departments of1Neurosurgery.

Journal of Neurosurgery
|December 17, 2018
PubMed
Abstract

Insights

Near-infrared (NIR) imaging with indocyanine green (ICG) and OTL38 shows high sensitivity for detecting pituitary adenomas. OTL38 is specific for nonfunctioning adenomas, while ICG is broadly applicable, aiding surgical resection.

Area of Science:

  • Neurosurgery
  • Oncology
  • Medical Imaging

Background:

  • Intraoperative molecular imaging enhances tumor resection rates.
  • Near-infrared (NIR) fluorophores offer better tissue penetration and reduced autofluorescence compared to visible-light agents.
  • Indocyanine green (ICG) and OTL38 are NIR fluorophores with different mechanisms for pituitary adenoma imaging.

Purpose of the Study:

  • To compare the properties of the second-window ICG (SWIG) technique and OTL38 for NIR imaging of pituitary adenomas.
  • To evaluate the potential of these NIR imaging modalities in neurosurgery for pituitary adenomas.

Main Methods:

  • 39 patients with pituitary adenomas were enrolled in two sequential studies.
  • 16 patients received systemic ICG 24 hours prior to surgery; 23 patients received OTL38 2-3 hours prior.
  • NIR fluorescence signal-to-background ratio (SBR) was measured, and immunohistochemistry for folate receptor-alpha (FRα) was performed on OTL38-treated samples.

Main Results:

  • ICG demonstrated strong NIR fluorescence (mean SBR 4.1) in all 16 adenomas, with no significant difference between functioning and nonfunctioning types.
  • OTL38 showed varying SBRs (1.7-3.2), with 100% sensitivity and specificity for FRα-overexpressing nonfunctioning adenomas.
  • SWIG had 100% sensitivity but 29% specificity; OTL38 had 75% sensitivity and 100% specificity for nonfunctioning adenomas.

Conclusions:

  • Intraoperative NIR fluorophore imaging is highly sensitive for pituitary adenoma detection.
  • OTL38 is specific for nonfunctioning adenomas, while SWIG is applicable to both types but less specific.
  • Targeted (OTL38) and non-targeted (SWIG) NIR fluorophores have distinct roles, potentially improving resection rates and patient outcomes.

Related Concept Videos

Hypothalamic-Pituitary Axis01:37

Hypothalamic-Pituitary Axis

The response to stress—be it physical or psychological, acute or chronic—involves activation of the Hypothalamic-Pituitary-Adrenal (HPA) axis. The HPA axis is part of the neuroendocrine system because it involves both neuronal and hormonal communication. Its function is to regulate homeostatic systems—metabolic, cardiovascular, and immune—providing the necessary means to respond to a stressor.
66.1K
Hormones of the Pituitary Gland01:27

Hormones of the Pituitary Gland

The small, pea-sized pituitary gland is located at the base of the brain. It is crucial in regulating various bodily functions, from growth to reproduction. The gland is divided into the anterior lobe and the posterior lobe. The secretory cell clusters in the pars distalis of the anterior pituitary lobe are controlled by hypothalamic regulators and synthesize six primary hormones.
The most abundantly secreted hormone from the anterior lobe is the growth hormone, which controls overall growth by...
10.4K
The Pituitary Gland01:17

The Pituitary Gland

The pituitary is a small endocrine organ in the sphenoid bone under the hypothalamus. Primarily, the pituitary in adults has two distinct anatomical and functional regions— the anterior and posterior lobes. During human fetal development, a third pituitary gland region called the pars intermedia atrophies and disappears. However, some of its cells migrate and exist adjacent to the anterior pituitary in adults.
10.8K
Passive Filters01:27

Passive Filters

Passive filters are utilized to shape the frequency spectrum of signals across a diverse array of applications. These filters, using only passive elements like resistors (R), inductors (L), and capacitors (C), are capable of selectively allowing or blocking certain frequency ranges without the need for external power sources.
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
1.0K
Active versus Passive Immunity01:31

Active versus Passive Immunity

Immunity, along with the ability to limit pathogen growth to prevent significant body tissue damage, can be gained either by (1) actively developing an immune response within the individual after exposure to a pathogen or after getting vaccinated or (2) passively transferring immune components from an immune individual to one who is nonimmune. Both these forms of immunity can be found naturally and in medical practices.
Active Immunity
Active immunity refers to the resistance one develops...
10.8K
Internal Receptors01:31

Internal Receptors

Many cellular signals are hydrophilic and therefore cannot pass through the plasma membrane. However, small or hydrophobic signaling molecules can cross the hydrophobic core of the plasma membrane and bind to internal, or intracellular, receptors that reside within the cell. Many mammalian steroid hormones use this mechanism of cell signaling, as does nitric oxide (NO) gas.
74.6K