The need for improved contrast media. Ioxilan: updating design theory
1Department of Radiology, University of California, San Diego.
Abstract:
Because of computed tomography (CT) and digital subtraction angiography (DSA), other diagnostic procedures assisted by urovascular contrast media (CM) have decreased, but the annual total remains at 10 to 11 million procedures since 1980. This trend, expected to continue, suggests that CM will remain vital to medical imaging. The current nonionic CM are not universally affordable, and may elicit pain in peripheral angiography. The author and co-workers explored conversion of ionic into nonionic CM, and have arrived at Ioxilan, 5-(N-2,3-dihydroxypropylacetamido)-2,4,6-triiodo-N-(2-hydroxyethyl )-N'-(2,3- dihydroxypropyl)-isophthalamide; a stable, water-soluble and well-tolerated CM. Ioxilan has unexpectedly low osmolality (570 mOsm at 300 mgI/mL), attributable to the region of double-methylenes that, by hydrophobic bonding, transiently associates the Ioxilan molecules. The high overall hydrophilicity, and thus good biological tolerance, of Ioxilan is accomplished by masking the hydrophobic region with a hydrophilic group. The author suggests that improved urovascular nonionic CM can be designed using this principle.
More Related Videos
07:26Synthesis of 68Ga Core-doped Iron Oxide Nanoparticles for Dual Positron Emission Tomography /(T1)Magnetic Resonance Imaging
Published on: November 20, 2018
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography