Formation of Thick Dense Yttrium Iron Garnet Films Using Aerosol Deposition
Published on: May 15, 2015
Prospective scintillation electron detectors for S(T)EM based on garnet film scintillators
Petr Schauer1, Ondřej Lalinský1, Miroslav Kučera2
1Institute of Scientific Instruments of the CAS, Brno, Czech Republic.
Abstract:
The performance of a scintillation electron detector for a scanning electron microscope and/or a scanning transmission electron microscope (S(T)EM) based on new epitaxial garnet film scintillators was explored. The LuGAGG:Ce and LuGAGG:Ce,Mg film scintillators with chemical formula (Ce0.01 Lu0.27 Gd0.74 )3-w Mgw (Ga2.48 Al2.46 )O12 were prepared and their cathodoluminescence (CL) and optical properties were studied and compared with the properties of current standard bulk single crystal YAG:Ce and YAP:Ce scintillators. More specifically, CL decay characteristics, CL emission spectra, CL intensities, optical absorption coefficients, and the refractive indices of the mentioned scintillators were measured. Furthermore, electron interaction volumes with absorbed energy distributions, photomultiplier (PMT) photocathode matchings, modulation transfer functions (MTF), and the photon transport efficiencies of scintillation detectors with the mentioned scintillators were calculated. A CL decay time for the LuGAGG:Ce,Mg film scintillator as low as 28 ns with an afterglow of only 0.02% at 1 μs after the e-beam excitation was observed. As determined from calculated MTFs, the scintillation detectors with the new film scintillators lose contrast transfer ability above 0.6 lp/pixel, while the currently commonly used YAG:Ce single crystal scintillators already do so above 0.1 lp/pixel. It was also calculated that the new studied film scintillators have an 8% higher photon transfer efficiency, even for a simple disk shape compared with the standard bulk single crystal YAG:Ce scintillator. The studied LuGAGG:Ce,Mg epitaxial garnet film scintillators were evaluated as prospective fast scintillators for electron detectors, not only in S(T)EM but also in other e-beam devices.
More Related Videos
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
Published on: January 6, 2016
09:49Routine Collection of High-Resolution cryo-EM Datasets Using 200 KV Transmission Electron Microscope
Published on: March 16, 2022
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Interaction of EM Radiation with Matter: Spectroscopy
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Dual Nature of Electromagnetic (EM) Radiation
Wavelength is the distance between two consecutive peaks (the highest point) or troughs (the lowest point) in the wave. Frequency is the number of...