Related Experiment Video
Updated: Jan 31, 2026

Immunoglobulin G N-Glycan Analysis by Ultra-Performance Liquid Chromatography
Published on: January 18, 2020
A hydrophobic deep eutectic solvent based vortex-assisted liquid-liquid microextraction for the determination of
Kaige Zhang1, Chuang Liu1, Shuangying Li1
1School of Environment, Henan Key Laboratory for Environmental Pollution Control, Key Laboratory for Yellow River and Huai River Water Environment and Pollution Control, Ministry of Education, Henan Normal University, Xinxiang, Henan, 453007, PR China.
Abstract:
Hydrophobic deep eutectic solvents (DESs) are a new class of green solvents, and their research and application are a brand new area. So far, only a few hydrophobic DESs have been reported as extraction solvents. In this paper, five kinds of hydrophobic DESs composed of trioctylmethylammonium chloride and hydroquinone, 4-phenylphenol or 4-cyanophenol are designed and prepared for the first time. Melting point / glass transition temperature and density are also determined for these DESs. Coupled with HPLC, these hydrophobic DESs have been used as extractants in vortex-assisted liquid-liquid microextraction for the selective enrichment and indirect determination of formaldehyde. The optimization of reaction and extraction conditions, such as pH value, reaction time and temperature, concentration of 2,4-dinitrophenylhydrazine, type and dosage of the extraction solvent, speed and time of vortex, salt addition and centrifugation time are investigated in detail. It is found that under the optimized experimental conditions, the calibration curve of this method is linear in the range of 1.0-200.0 μg L-1 with the linear correlation coefficient (r2) of 0.9994. The limit of detection (S/N = 3) and limit of quantification (S/N = 10) are 0.2 μg L-1 and 1.0 μg L-1, and the intra-day and inter-day precision (RSD, n = 5) are 1.1% and 3.5%, respectively. The interference of some common coexisting ions and neutral molecules have been also tested. The proposed method has been successfully used for the determination of formaldehyde from biological and indoor air samples. The recovery of formaldehyde is in the range from 83.1% to 104.4%, and the relative standard deviation is lower than 5.9%. Furthermore, the analytical parameters of the proposed method have been compared with other extraction and microextraction methods.
More Related Videos
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
07:10Untargeted Liquid Chromatography-Mass Spectrometry-Based Metabolomics Analysis of Wheat Grain
Published on: March 13, 2020
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Molecular Comparison of Gases, Liquids, and Solids
Rise of Liquid in a Capillary Tube