An inter-centre statistical scale standardisation for quantitatively evaluating prostate tissue on T2-weighted MRI
Neda Gholizadeh1, Todsaporn Fuangrod2, Peter B Greer3,4
1School of Health Sciences, University of Newcastle, Callaghan, NSW, Australia. neda.gholizadeh@uon.edu.au.
Abstract:
Magnetic resonance images (MRI) require intensity standardisation if they are used for the purpose of quantitative analysis as inherent variations in image intensity levels between different image sets are manifest due to technical factors. One approach is to standardise the image intensity values using a statistically applied biological reference tissue. The aim of this study is to compare the performance of differing candidate biological reference tissues for standardising T2WI intensity distributions. Fifty-one prostate cancer patients across two centres with different scanners were evaluated using the percentage interpatient coefficient of variation (%interCV) for four different biological references; femoral bone marrow, ischioanal fossa, obturator-internus muscle and bladder urine. The tissue with the highest reproducibility (lowest %interCV) in both centres was used for intensity standardisation of prostate T2WI using three different statistical measures (mean, Z-score, median + Interquartile Range). The performance of different standardisation methods was evaluated from the assessment of image intensity histograms and the percentage normalised root mean square error (%NRSME) of the healthy peripheral zone tissue. Ischioanal fossa as a reference tissue demonstrated the highest reproducibility with %interCV of 18.9 for centre1 and 11.2 for centre2. Using ischioanal fossa for statistical intensity standardisation and the median + Interquartile Range method demonstrated the lowest %NRMSE across centres for healthy peripheral zone tissues. This study demonstrates ischioanal fossa as a preferred reference tissue for standardising intensity values from T2WI of the prostate. Subsequent image standardisation using the median + Interquartile Range intensity of the reference tissue demonstrated a robust and reliable standardisation method for quantitative image assessment.
Related Concept Videos
Statistical Significance
pH Scale
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
Probability in Statistics
An example of a simple event is a coin toss. The result of a coin toss is either a head or a tail. Here, head and tail are two simple events. These two simple events make up the sample space. Further, the probability of an event occurring falls within the range of 0 to 1. The probability of an...
Introduction to Statistics
In statistics, the collection of individuals or objects under study is called population. The idea of sampling is to select a portion of the larger population...
Atomic Weight