Related Experiment Video
Updated: Jan 30, 2026

Automation of a Positron-emission Tomography PET Radiotracer Synthesis Protocol for Clinical Production
Published on: October 26, 2018
Identification, Characterization, and Optimization of Integrin αvβ₆-Targeting Peptides from a One-Bead One-Compound
Yng Sarah C Tang1, Ryan A Davis2, Tanushree Ganguly3
1Department of Internal Medicine, Division of Hematology/Oncology, University of California, Davis and Sacramento, CA 95817, USA. yngtang@ucdavis.edu.
Abstract:
The current translation of peptides identified through the one-bead one-compound (OBOC) technology into positron emission tomography (PET) imaging agents is a slow process, with a major delay between ligand identification and subsequent lead optimization. This work aims to streamline the development process of 18F-peptide based PET imaging agents to target the integrin αvβ₆. By directly identify αvβ₆⁻targeting peptides from a 9-mer 4-fluorobenzoyl peptide library using the on-bead two-color (OBTC) cell-screening assay, a total of 185 peptide beads were identified and 5 beads sequenced for further evaluation. The lead peptide 1 (VGDLTYLKK(FB), IC50 = 0.45 ± 0.06 μM, 25% stable in serum at 1 h) was further modified at the N-, C-, and bi-termini. C-terminal PEGylation increased the metabolic stability (>95% stable), but decreased binding affinity (IC50 = 3.7 ± 1 μM) was noted. C-terminal extension (1i, VGDLTYLKK(FB)KVART) significantly increased binding affinity for integrin αvβ₆ (IC50 = 0.021 ± 0.002 μM), binding selectivity for αvβ₆-expressing cells (3.1 ± 0.8:1), and the serum stability (>99% stable). Our results demonstrate the challenges in optimizing OBOC-derived peptides, indicate both termini of 1 are sensitive to modifications, and show that further modification of 1 is necessary to demonstrate utility as an 18F-peptide imaging agent.
More Related Videos
09:5718F-Labeling of Radiotracers Functionalized with a Silicon Fluoride Acceptor SiFA for Positron Emission Tomography
Published on: January 11, 2020
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Integrins
Some ECM proteins assemble into a basement membrane to which the remaining components adhere. Proteoglycans typically form the bulk of the ECM while fibrous proteins, like collagen,...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Activation of Integrins
In "outside-in signaling," external factors in the extracellular space bind to exposed ligand binding sites on integrins. This causes the inactive protein to undergo a conformational change to become active. Integrins are often clustered on the cell membrane. Repetitive and regularly spaced ligand binding...
Emission Spectra