Acoustic Stimulation by Shunt-Diode Pre-Linearizer using Very High Frequency Piezoelectric Transducer for Cancer
1Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea.
Abstract:
In this paper, we proposed cancer cell acoustic stimulation by shunt-diode pre-linearizer scheme using a very high frequency (≥100 MHz) piezoelectric transducer. To verify the concept of our proposed scheme, we performed pulse-echo detection, and accessed therapeutic effects of human cervical cancer cells exposed to acoustic stimulation experiments using 100 MHz focused piezoelectric transducer triggered by PA with and without the proposed shunt-diode pre-linearizer scheme. In the pulse-echo detection responses, the peak-to-peak voltage of the echo signal when using the PA with shunt-diode pre-linearizer (49.79 mV) was higher than that when using the PA alone (29.87 mV). In the experimental results, the cell densities of cancer cells on Day 4 when using no acoustic stimulation (control group), the very high-frequency piezoelectric transducer triggered by PA only and PA combined with proposed pre-linearizer schemes (1 V and 5 V DC bias voltages) showed 100%, 92.8 ± 4.2%, 84.2 ± 4.6%, and 78 ± 2.9%, respectively. Therefore, we confirmed that the shunt-diode pre-linearizer could improve the performances of the pulse signals of the PA, thus, enabling better therapeutic stimulation performances for cancer cell suppression.
More Related Videos
06:51Microparticle Manipulation by Standing Surface Acoustic Waves with Dual-frequency Excitations
Published on: August 21, 2018
09:01Magnetic-, Acoustic-, and Optical-Triple-Responsive Microbubbles for Magnetic Hyperthermia and Pothotothermal Combination Cancer Therapy
Published on: May 22, 2020
Related Concept Videos
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Shunt Admittances
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
Zener Diodes
The Ideal Diode
Diode: Forward bias
The behavior of a diode in forward bias...