Related Experiment Video
Updated: Jan 30, 2026

Air Filter Devices Including Nonwoven Meshes of Electrospun Recombinant Spider Silk Proteins
Published on: May 8, 2013
Safety and efficiency of the fifth generation Woven EndoBridge device: technical note
Cristian Mihalea1,2, Jildaz Caroff1, Igor Pagiola1,3
1Department of Interventional Neuroradiology Neuro Brain Vascular Center, Hopital Bicetre, APHP, Paris Sud Université, Le Kremlin-Bicetre, Île-de-France, France.
Backround:
The treatment of wide neck bifurcation aneurysms remains challenging despite the introduction of new techniques (Y stenting, waffle cone technique, or flow diverter stents). The Woven EndoBridge (WEB) device is an innovative solution for this type of cerebral aneurysm. A new WEB 17 is now available and has been designed to offer smaller sized devices to optimize navigability and delivery.
Methods:
Between February 2017 and April 2018 all patients treated with the WEB 17 device in our center were retrospectively reviewed. 25 patients with 28 non-ruptured aneurysms were identified and analyzed. Three patients with two aneurysms both treated with the WEB device were identified.
Results:
The device was successfully deployed in all cases. Procedure related morbidity was 4% and mortality was 0%. In one case, a delayed postprocedural thromboembolic event occurred owing to device protrusion. Technical success, complications, angiographic outcomes, procedural data, and follow-ups are reported. The modified Rankin Scale score at discharge was 0 for 24 patients (96%). At the 3, 6, or 9 month follow-up, angiograms were taken of 21 of the 25 patients (84%) (24 of 28 aneurysms had been controlled); 3 patients (3 aneurysms) did not receive angiographic follow-up at the time of submission of this work. Complete occlusion was achieved in 22 of 24 aneurysms (91.66%), and 2 of 24 aneurysm (8.33%) showed a neck remnant.
Conclusions:
The WEB 17 is safe and technically feasible, according to this retrospective single center analysis. For very small bifurcation aneurysms, the WEB 17 seems to have lower complication rates than stent assisted techniques. However, further studies are needed to evaluate the complication rate and long term efficiency.
More Related Videos
05:54Stereo-Electro-Encephalo-Graphy SEEG With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
Published on: June 13, 2016
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
Related Concept Videos
Survey Safety
Household Wiring And Electrical Safety
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Production Efficiency
Trophic Efficiency