Related Experiment Video
Updated: Jan 30, 2026

Using Micro-Electro-Mechanical Systems MEMS to Develop Diagnostic Tools
Published on: October 1, 2007
The Research on Actuation Performance of MEMS Safety-and-Arming Device with Interlock Mechanism
Tengjiang Hu1, Wei Ren2,3, Yulong Zhao4
1State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Xi'an 710049, China. htj047@xjtu.edu.cn.
Abstract:
Micro-electromechanical systems (MEMS) safety-and-arming (S&A) device shows great potential in munition miniaturization, and it can be seen as the symbol of the fourth generation of weapons systems. In this paper, the design, fabrication, and actuation performance of a silicon based S&A device is presented. It is a multilayer stacked device, which is composed of the cover plate, the actuation chip, and the barrel plate. The electro-thermal principle is investigated in MEMS scale. With 11 V driving voltages, the structure of V-shape actuator, pawl, and slider can generate 100 μm and 45 μm displacement, and realize pulling, disengaging, and reengaging to change the device from the safety position into armed position smoothly (550 μm displacement). The rack and interlock mechanism formed by the pawl and slider gives the device the features of linear output displacement, low power consumption, input signal recognition, and sustained displacement. The 20,000 g setback acceleration is applied, and no structure damage can be found after the impact, which indicates the good anti-load ability of the MEMS S&A device. In order to solve the contradiction between the functional structure and the fabrication process, different structures are designed separately on different wafers. Both silicon and SOI wafers are used in the fabrication process, and the S&A device has been minimized into 8.5 mm × 8.5 mm × 0.8 mm successfully.
More Related Videos
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
10:39Using a Microfluidics Device for Mechanical Stimulation and High Resolution Imaging of C. elegans
Published on: February 19, 2018
Related Concept Videos
Survey Safety
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...
Household Wiring And Electrical Safety
Mechanical Protein Functions
Reaction Mechanisms
For instance, the decomposition of ozone appears to follow a mechanism with two steps:
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...