To measure peripapillary retinal nerve fiber layer (RNFL) thickness and posterior pole retinal thickness in primary angle-closure suspects (PACS) by Spectral domain optical coherence tomography (SD-OCT) and to be compared with normal subjects.
Methods:
Thirty five primary angle-closure suspect patients and thirty normal subjects were enrolled in this study. Peripapillary RNFL and posterior pole retinal thickness by posterior pole asymmetry analysis (PPAA) in SD-OCT were measured.
Results:
No significant difference was found in both groups on age, sex distribution, refractive error, intraocular pressure (IOP) and axial length. The PACS group exhibited significantly thinner macular retinal thickness and larger asymmetry on posterior pole region compared with the control group. Yet no significant difference of peripapillary RNFL parameters was found between PACS group and normal control group. A negative correlation was observed between the total retinal thickness on posterior pole region and age when all the PACS participants were analyzed.
Conclusions:
Posterior pole retinal thickness measurements obtained by Heidelberg Spectralis SD-OCT using PPAA showed significant thinner change in PACS group than healthy controls. Only age seemed to be an indicator in the occurrence of glaucomatous damage in PACS patients.
Related Concept Videos
Angle Closure Glaucoma: Treatment
Pole and System Stability
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
Membrane Asymmetry Regulating Transporters
Flippase
Eukaryotic flippases are type-IV P-type ATPases or P4-ATPases belonging to P-type ATPase family proteins that are membrane-bound pumps involved in the ATP-mediated transport of ions and molecules across the membrane. Flippases flip specific phospholipids from the outer to the inner leaflet of a membrane. All P4-ATPases have one...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle of Twist: Problem Solving