Related Experiment Video
Updated: Jan 29, 2026

Three-Dimensional Finger Motion Tracking during Needling: A Solution for the Kinematic Analysis of Acupuncture Manipulation
Published on: October 28, 2021
Determining the change in length of the anterolateral ligament during knee motion: A three-dimensional optoelectronic
Thomas Neri1, Rodolphe Testa2, Loic Laurendon3
1Univ Lyon - UJM-Saint-Etienne, Inter-university Laboratory of Human Movement Science, EA 7424, F-42023 Saint-Etienne, France; Department of Orthopedic Surgery, University Hospital of Saint Etienne, France; Sydney Orthopaedic Research Institute, Sydney, Australia.
Background:
The variation of the anterolateral ligament (ALL) length during knee motion is still unclear, and the knee position in which a reconstruction graft should be tensioned remains controversial. The objective of this study was to determine the variation of the ALL length during knee motion using a three-dimensional optoelectronic system.
Methods:
Kinematic analyses of 20 cadaveric knees were performed using a Motion Analysis® system. The variability of the measurements made during the five acquisition cycles was studied. Reliability was evaluated by two separate measurement sessions, with complete system reinstallation, using different cadavers and a new operator. The ALL length was analysed from extension to full flexion in three rotational conditions.
Findings:
When analysing the reliability of the five cycles, 82% of the measurements we found to have an Intra Class Correlation (ICC) >0.85. The reproducibility of inter-sessional measures by different operators and different cadavers was either good (ICC >0.75) or excellent (ICC >0.85). The ALL length was maximum in full internal rotation with the knee at 25° of flexion.
Interpretation:
This three-dimensional optoelectronic protocol allowed us to analyse the variation of the ALL length during intact knee motion with good reliability and the required accuracy to analyse this variable. The maximal length and highest tension of the ALL was reported at 25° of knee flexion in internal rotation, suggesting this as the optimal position for the knee joint when tensioning an ALL reconstruction.
Related Concept Videos
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Dimensional Analysis
Dimensional analysis allows us to analyze and compare physical quantities on a...
Dimensional Analysis
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Problem Solving: Dimensional Analysis

